期刊文献+

三电极结构荫罩式PDP的模拟和实验研究

Investigation to three-electrode shadow mask plasma display panel by fluid simulation and panel experiment
在线阅读 下载PDF
导出
摘要 采用三维流体模型和老炼测试平台从理论模拟和实验测试角度研究三电极结构荫罩式PDP在对向放电和表面放电驱动波形下的放电发光特性.模拟结果表明:三电极结构荫罩式PDP在对向放电驱动波形下的点火和维持电压都低于表面放电驱动波形下的点火和维持电压;对向放电驱动波形的峰值亮度比表面放电驱动波形约高89%,表面放电驱动波形的放电效率比对向放电驱动波形约高9.1%.老炼平台的实验测试结果也表明了同样的趋势. Three-dimensional fluid model and the aging system are used to investigate the characteristics of three-electrode shadow mask plasma display panel (PDP) cell in two types of driving waveforms. The simulation results indicate that the firing and sustaining voltages driven by opposite-discharge waveforms are lower than those driven by surface-discharge waveforms. The simulation results also show that the peak discharge intensity driven by opposite-discharge waveforms is 89% higher than that driven by surface-discharge waveforms, while the discharge efficiency driven by surface-discharge waveforms is 9. 1% higher than that driven by opposite-discharge waveforms. The luminance and luminous efficiency tested in experimental panel show the same variations with the simulation results.
出处 《东南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2008年第4期611-616,共6页 Journal of Southeast University:Natural Science Edition
基金 国家自然科学基金资助项目(60571033)
关键词 流体模型 三电极结构荫罩式PDP 放电效率 发光效率 亮度 fluid model three-electrode shadow mask plasma display panel discharge efficiency luminous efficiency luminance
  • 相关文献

参考文献12

  • 1王林生,周健,文小强,赖华生.PDP与LCD两大平板显示技术探析[J].江西有色金属,2007,21(4):31-33. 被引量:2
  • 2Tu Yan, Zhang Xiong, Yang Lanlan, et al. Three dimensional investigation of a novel plasma display panel with metal barrier plates [ C ]//SID 02 Digest. Boston, USA ,2002 : 404 -408.
  • 3Zhang Xiong, Li Qing, Tu Yan, et al. A novel AC PDP with shadow mask [ C ]//SID02 Digest. Boston, USA,2002:748 - 752.
  • 4Zhang Xiong, Li Qing, Tu Yan, et al. A novel shadow mask PDP with high luminance and contrast [ C]//SID 03 Digest. Baltimore,USA,2003 : 149 - 151.
  • 5Tang Yongming, Zhang Xiong, Li Qing, et al. A 25inch SMPDP with fine pitch and high resolution [ C ]// SID 05 Digest. Boston, USA,2005:214 -217.
  • 6Zhang Xiong, Tu Yan, Li Qing, et al. 42-inch wide XGA shadow mask PDP without ITO [ C ]//IDW 06. Otsu, Japan,2006 : 1793 - 1796.
  • 7李青,张雄,樊兆雯,等.表面放电型荫罩式等离子体显示板:中国,200610041329.8[P].2006-08-15.
  • 8Yang Lanlan, Tu Yan, Zhang Xiong, et al. Effects of ramp reset pulses on the address discharge in a shadow mask plasma display panel [ J ]. Plasma Sources Science Technology ,2007 ( 16 ) : 392 - 398.
  • 9Shin B J, Choi K C, Whang K W. Characteristics of a wall voltage during sustain period in AC plasma display panels [ l ]. IEEE Transactions on Plasma Science ,2005, 33(2) : 964 -968.
  • 10Meunier J, Belenguer Ph, Boeuf J P. Numerical model of an AC plasma display panel cell in neon-xenon mixtures [ J ]. Journal of Applied Physics, 1995,78 (2) :731 -745.

二级参考文献16