期刊文献+

Application of Electrical Capacitance Tomography to the Concentration Measurement in a Cyclone Dipleg 被引量:5

Application of Electrical Capacitance Tomography to the Concentration Measurement in a Cyclone Dipleg
在线阅读 下载PDF
导出
摘要 Accurate solid concentration measurement plays a key role in the process industry. Measurements analyzed offline can be used to estimate process efficiencies, to identify problems in a flow, and to validate computational models. Online measurements can be used for active control. Electrical capacitance tomography (ECT) is a unique measuring technique with great potential in multiphase flow measurement. Experimental studies are carried out on a solid concentration measurement in a cyclone separator dipleg, using ECT. In this experiment eight electrodes are selected for the ECT sensor that is placed on the straight tube of the dipleg. The fluctuating characteristics according to the screw feeder and the effect of the airflow rate from the top of the cyclone are analyzed. The feasibility andreliability of the method are verified by the experimental results. 精确稳固的集中测量在过程工业起一个关键作用。脱机分析的大小能被用来估计过程效率,以在流动识别问题,并且验证计算模型。联机大小能被用于活跃控制。电的电容断层摄影术(ECT ) 是有在多相的流动测量的大潜力的一种唯一的测量技术。试验性的研究在气旋隔板 dipleg 在稳固的集中大小上被执行,用 ECT。在这个实验,八个电极为被放在 dipleg 的直试管上的 ECT 传感器被选择。根据螺丝钉, feeder 和气流的效果从气旋的顶评估的波动的特征被分析。方法的可行性和可靠性被试验性的结果验证。
出处 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第4期635-639,共5页 中国化学工程学报(英文版)
基金 Supported by the National Natural Science Foundation of China (60672151, 60532020).
关键词 electrical capacitance tomography concentration measurement cyclone separator dipleg gas-solid two-phase flow 电容层析成像技术 分离器 料腿 浓度测量
  • 相关文献

参考文献3

二级参考文献23

  • 1余金华,冀海峰,黄志尧,李海青.电阻层析成像有限元分析若干技巧[J].仪器仪表学报,2003,24(z2):687-689. 被引量:2
  • 2Deckwer,W.D.,Bubble Column Reactors,John Wiley,Chichester (1992).
  • 3Nigam,K.D.P.,Schumpe,A.,Three-phase Spargered Reactors,Gordon & Breach,Amsterdam (1996).
  • 4Dudukovic,M.P.,"Opaque multiphase reactors:Experimentation,modelling and troubleshooting",Oil Gas Sci.Technol.,55(2),135-158 (2000).
  • 5Jin,H.,Yang,S.,Zhang,T.,Tong,Z.,"Bubble behaviour of a large-scale bubble column with elevated pressure",Chem.Eng.Technol.,27(9),1007-1013 (2004).
  • 6Jin,H.,Yang,S.,He,G.,Guo,Z.,Tong,Z.,"An experimental study of holdups in large-scale p-xylene oxidation reactor using gamma-ray attenuation approach",Chem.Eng.Sci.,60,5955-5961(2005).
  • 7Reinecke,N.,Petritsch,G.,Schmitz,D.,Mewes,D.,"Tomographic measurement techniques-visualization of multiphase flows",Chem.Eng.Technol.,21,7-18(1998).
  • 8Xie,C.G.,Reinecke,N.,Beck,M.S.,Mewes,D.,Williams,R.A.,"Electrical tomography techniques for process engineering applications",Chem.Eng.J.,56,127-133 (1995).
  • 9Veera,V.P.,"Gamma ray tomography design for the measurement of hold-up profiles in two-phase bubble columns",Chem.Eng.J.,81,251-260 (2001).
  • 10Shollenberger,K.A.,Torczynski,J.R.,Adkins,D.R.,"Gamma-densitometry tomography of gas holdup spatial distribution in industrial scale bubble columns",Chem.Eng.Sci.,52(3),2037-2048 (1997).

共引文献17

同被引文献50

引证文献5

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部