期刊文献+

不同大连接体对支持组织受力影响的光弹实验分析 被引量:4

Photoelastic Stress Analysis of Supporting Structures by Different Major Connectors
在线阅读 下载PDF
导出
摘要 作者采用光弹实验应力分析法,研究了不同大连接体设计的上下颌单侧游离端义齿,在侧向加载时对基牙和缺牙区牙槽嵴的受力情况。结果表明,腭杆传递(牙合)力的作用在一定范围内受其宽度影响很小;义齿在侧向载荷下,(牙合)力主要由缺牙区牙槽嵴和同侧基牙承担;舌杆、双舌杆和舌板传递给基牙和缺牙区牙槽嵴的作用力未见明显差异。 Photoelastic models were used to visualize stresses developed in the abutment teeth and the edentulous region by distal - extension removable partial dentures with different palatal bars and lingual bars. Evaluation of the load - transfer characteristics of the various designs was based on comparison of the recorded isochrornatic fringe distributions,The following can be concluded; (1) Different width of palatal bars did not generate different stresses. (2)The edentulous region and abutment were the main supporting structures. The abutment on the opposite side shared a small part of the load. (3)No significant different stresses were developed by the three types of mandibular major connectors.
出处 《上海生物医学工程》 1997年第3期15-18,共4页 Shanghai Journal of Biomedical Engineering
关键词 义齿 光弹实验 游离端义齿 大连接体 Removable Partial Dentures Lateral Load Photoelastie Stress Analysis Major Connectos
  • 相关文献

参考文献3

二级参考文献5

  • 1魏治统,杜传诗,赵云凤,叶德临,杨建民,矫鲁桂.用光弹性方法对固定桥基牙牙槽骨受力的实验研究[J]华西口腔医学杂志,1984(02).
  • 2张汉清.早期接触对牙周支持组织的光测弹性应力模型测定[J]口腔医学,1984(01).
  • 3姚月玲,周敬行,汪文骏.游离端义齿近、远中支托的光弹应力分析[J]第四军医大学学报,1983(01).
  • 4汪文骏,张成藩,杨云曙,徐鹤廷.游离端活动部分义齿的电测法应力分析(三)——结论及临床意义[J]口腔医学,1985(02).
  • 5朱希涛,白沁,周辛庚,章玮宝,刘春阳.完全固定桥与半固定桥受力状况的激光全息分析[J]中国生物医学工程学报,1985(01).

共引文献23

同被引文献37

  • 1李锦标,史书俊,刘雅琳,李长义,候晓明,张连云,高瑞亭.RPI及三臂卡环对游离端义齿支持组织应力分布的影响——三维光弹法观测[J].实用口腔医学杂志,1993,9(1):19-21. 被引量:3
  • 2包美星,蔡玉惠,项尚,张抱和,何小元.R.P.I卡环的光弹性应力分析及临床观察[J].南京医科大学学报(自然科学版),1994,14(2):222-224. 被引量:2
  • 3陈亚明,周书敏.合支托优化设计的理论探讨[J].实用口腔医学杂志,1995,11(2):89-92. 被引量:5
  • 4皮昕.口腔解剖生理学(第5版)[M].北京:人民卫生出版社,2003..
  • 5Sheikh HA.Section impressions for mandibular distal extension removable partial denture[J].J Prosthet Dent,1998,80(2):216-219.
  • 6Ben-Ur Z.Further aspects of design for distal extension removable partial denture based on the kennedy classification[J].J Oral Rehabil,1999,26(2):165-169.
  • 7Frechette R.The influences of partial denture design on distribution of force to abutment teeth[J].J Prosthet Dent,2001,85(6):527-539.
  • 8Beschnidt SM.Telescopic crown-retained removable partial dentures.review and case report[J].Compend Contin Educ Dent,2001,22(11):927-934.
  • 9Igarashi Y,Ogata A,Kuroiwa A,et al.Stress distribution and abutment tooth mobility of distal-extension removable partial denture with different retainers:an in vivo study[J].J Oral Rehail,1999,26(2):111-116.
  • 10Kyuho LE.Double impression procedure for removable denture retained with semiprecision attachment[J].J Prosthet Dent,1996,75(6):583-587.

引证文献4

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部