摘要
根据干式空心电抗器的结构特点,阐述了干式空心电抗器的电流分布与损耗。通过对计算程序、制造工艺、原材料使用的分析,指出了干式空心电抗器环流损耗产生的原因,提出了解决环流损耗的途径。
According to the structural features of dry-type air-core reactor, its loss and current distribution are introduced in this paper. The reason of generating circular current loss in dry-type air-core reactor is expounded, and the way of reducing the loss is presented through analysis of calculating program, processing and the use of raw material.
出处
《变压器》
EI
北大核心
1997年第12期6-8,共3页
Transformer
关键词
空心电抗器
干式
电流分布
损耗
电抗器
Air-core reactor, Dry-type, Current, Distribution, Loss