摘要 目的探讨64排螺旋CT冠状动脉造影成像技术在图像质量控制方面的应用价值。方法回顾性分析CT冠状动脉造影的临床疑诊冠心病患者366例,将原始数据传至工作站,行多平面重建(MPR)、容积重建(VR)、最大密度投影(MIP)和曲面重建(CPR)等后处理,研究64排螺旋CT冠状动脉造影成像技术及成像质量的影响因素。结果366名受检者,冠状动脉显示成功率96.7%,优良率82.2%,心率及心率波动与冠状动脉图像质量呈负相关(r=0.905)。当心率相对较高时,使用SSB扫描的冠状动脉图像质量要优于SSEG扫描。结论合理选择CT冠状动脉造影扫描和后处理技术,可以提高图像质量和检查的可靠性。 Objective To explore the application values of imaging techniques in the quality control of images of 64-slice spiral CT coronary angiography. Methods Data of 366 patients suspected to have coronary artery diseases and undergoing 64-slice CTA were retrospectively analyzed. Imaging techniques and influent factors of the images quality were studied. Resuits Coronary arteries were successfully depicted in 354 patients (96.7%), and the images were excellent in 301 (82.2%) of them. The heart rate and its fluctuation were negatively related to the coronary image quality (r=0. 905). When the patient's heart rate was relatively higher, the quality of images in SSB scan mode was superior to image of SSEG scan mode. Conclusion The reasonal selection of scan mode and the after-treatment technology is helpful to improve image quality and dependability of examination in 64-slice spiral CT coronary angiography.
出处 《中国医学影像技术》 CSCD 北大核心 2008年第10期1657-1660,共4页 Chinese Journal of Medical Imaging Technology
关键词 体层摄影术 X线计算机 冠状动脉血管造影 冠状动脉疾病 Tomography, X-ray computed Coronary angiography Coronary disease
  • 相关文献

参考文献12

  • 1Schuijf JD, Bax J J, Jukema JW, et al. Noninvasive evaluation of the coronary arteries with multi-slice computed tomography in hypertensive patients. Hypertensive, 2005,45 (2) : 227-232.
  • 2Mollet NR, Cademartiri F, Nieman K, et al. Multi-slice spiral computed tomography coronary angiography in patients with stable angina pectoris. J Am Coll Cardiol, 2004,43(12) : 2265-2270.
  • 3Nilolaou K, Flohr T, Knez A, et al. Advances in cardiac CT imaging: 64-slice scanner. Int J Cardiovasc Imaging, 2004,20(6):535- 540.
  • 4Vogl J, Abolmaali N D, Diebold T, et al. Techniques for the detection of coronary atherosclerosis: multi-detector row CT coronary angiography. Radiology, 2002,223 ( 1 ) : 212-220.
  • 5Hong C, Becker CR, Huber A, et al. ECG-gated reconstructed multi-detector row CT coronary angiography: effect of varying trigger delay on image quality. Radiology, 2001,220(3) :712-717.
  • 6孟冷,张兆琪,吕飚,于薇,晏子旭.64排螺旋CT冠状动脉成像误诊分析[J].中国介入影像与治疗学,2008,5(3):187-192. 被引量:11
  • 7Begemann PG, Stevendaal UV, Manzke R, et at. Evaluation of spatial and temporal resolution (Review). Eur Radiol, 2005, 15 (Suppl 2) :B2-B9.
  • 8Wintersperger BJ, Nikolaou K. Basics of cardiac MDCT: techniques and contrast application (Review). Eur Radiol, 2005, 15 (Suppl 2) :B2-B9.
  • 9蒋学祥,邱建星,刘剑,王继琛,高莉,孙晓伟,秦乃姗.64层螺旋CT评估冠状动脉狭窄的准确性——与传统冠状动脉造影对照研究[J].中国医学影像技术,2006,22(10):1472-1476. 被引量:49
  • 10綦维维,武靖,杜湘珂,李剑颖.64层螺旋CT心脏冠状动脉检查质量控制和扫描参数优化研究[J].中华放射学杂志,2006,40(12):1322-1325. 被引量:36

二级参考文献34

共引文献92

同被引文献64

引证文献14

二级引证文献99

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部