期刊文献+

具有窄谱特性的X光管原型设计与GEANT4仿真 被引量:3

Prototype design of an X-ray tube with narrow spectrum and GEANT4 simulations
在线阅读 下载PDF
导出
摘要 为获得近似单能的窄谱X射线源,本文设计了一种双靶结构的X光管。仿真实验结果表明通过设置不同材料的靶可以得到不同能量段的窄谱X射线。由于第二个靶设置在X光管的外部,可以方便的实现能量切换。此外,本文还利用仿真方法验证了窄谱X射线源在减轻硬化伪影方面的作用。本文的研究结果可为研制窄谱X射线源提供参考。 In order to generate X-ray with narrow spectrum, we design a novel X-ray tube which is of dualtarget structure. We have performed computer simulation to verify the validity of this design, using Monte Carlo simulation package GEANT4. Simulation results show that X-ray with narrow spectrums which condense on a certain energy band corresponding to the material of targets can be generated. Moreover, the effectiveness of narrow spectrum X-ray in comparison with broad spectrum X-ray in reducing beam-hardening artifacts is demonstrated. Also, the work can provide references for researchers and manufacturers who want to acquire X-ray source with narrow spectrum.
作者 邹晶 王文彬
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2008年第5期999-1004,共6页 Nuclear Electronics & Detection Technology
基金 国家自然科学基金(60472071 60532080) 北京市自然科学基金(4051002)
关键词 窄谱X射线 仿真 GEANT4 双靶X光管 X-ray with narrow band spectrum simulation GEANT4 dual-target X-ray tube
  • 相关文献

参考文献1

二级参考文献14

  • 1Jiang Hsieh.Computed Tomography Principles, Design, Artifacts, and Recent Advances[M] .SPIE PRESS, 2004.
  • 2Ge Wang, Donald L. Snyder, Joseph. A. O'Sullivan, Michael W. Vannier.Iterative Deblurring for CT Metal Artifact Reduction[J].IEEE Trans. Med. Imag., vol. 15, pp.657-664, 1996.
  • 3G.T. Herman and Lent A.Iterative reconstruction Algorithm[J].Computers in Biology and Medicine, vol. 6, pp.273-294, 1976.
  • 4B. De Man, J. Nuyts, P. Dupont, G. Marchal, and P. Suetens.Reduction of Metal Streak Artifacts in X-ray Computed Tomography Using A Transmission Maximum A Posteriori Algorithm[J].IEEE Trans. Nuc. Sci., vol.47, No.3, pp.977-981, 2000.
  • 5Shiying Zhao, Douglas D. Robertson, Ge Wang, Bruce Whiting, and Kyongtae T. Bae.X-Ray CT Metal Artifact Reduction Using Wavelets: An Application for Imaging Total Hip Prostheses[J].IEEE TRAN. Med. Imag. vol.19, NO.12, pp.1238-1247, 2000.
  • 6Shiying Zhao, Kyongtae T. Bae, Bruce Whiting and Wang Ge.A wavelet method for metal artifact reduction with multiple metallic objects in the field of view [J].Journal of X-ray Science and Technology 10, pp. 67-76, IOS PRESS, 2002.
  • 7Laigao Chen, Yun Liang, George A Sandison, et al. A novel method for reducing high attenuation object artifacts in CT reconstructions[C].Proceedings of SPIE, 4684: pp. 841-850, 2002.
  • 8G. T. Herman.Correction for beam hardening in computed tomography[J].Phys. Med. Biol., vol. 24(1), 81-106, 1979.
  • 9P. Hammersberg, et al.Correction for beam hardening artifacts in computerized tomography[J].Journal of X-ray Science and Technology, vol. 8 (1), 75-93, 1998.
  • 10Sabee Molloi, Yifang Zhou, and Greg Wamsely.Scatter-Glare Estimation for Digital Radiographic Systems: Comparison of Digital Filtration and Sampling Techniques[J].IEEE Trans. Med. Imag, vol.17, No. 6: 881-888, 1998.

共引文献22

同被引文献10

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部