期刊文献+

三种牙齿工作长度测量方法的比较研究 被引量:5

Comparative study on the rate of corespondent of working length determined by three methods
在线阅读 下载PDF
导出
摘要 目的:研究三种牙齿根管工作长度测量方法的符合率。方法:选取临床上需进行根管治疗术的患牙153个(358个根管),使用TRI AUTO ZX根管治疗仪确定牙齿工作长度,与X线诊断丝照相法和器械探查法进行对比,研究3种牙齿工作长度测量法的符合率。结果:电测法与X线诊断丝照相法比较,符合率为92.46%,电测法与器械探查法比较,符合率为67.88%;X线诊断丝照相法与器械探查法比较,符合率为64.53%。结论:牙齿长度电测法是一种比较准确、客观的测量牙齿工作长度的方法。 AIM: To evaluate the rate of coresppondent of working length determined by three methods. METHODS: Patents with 153 teeth with 358 root canals needing root canal therapy were selected clinically. TIR AUTO ZX root canal apex locator was applied for the determination of the working length. The working length measured with root canal apex locator was compared with X - ray photogrammetry and defction method using dental instrument. RESULTS: The rate of corespondent of working length determined by TRI AUTO ZX root canal apex locator was 92.46% compared with X- ray photogrammetry, 67.88% compared with detection mcthod using dental instrument, and the rate of corespondent of working length determination by X - ray photogrammetry is 64.53% compared with detection method using dental instrument. CONCLUSION: The method of root canal length measured with TRI AUTO ZX root canal apex locator is one kind of accurate and impersonal one.
出处 《牙体牙髓牙周病学杂志》 CAS 2008年第12期693-695,共3页 Chinese Journal of Conservative Dentistry
关键词 根管 牙齿工作长度 根管治疗仪 准确性 root canal root canal working length root canal apex locator accuracy
  • 相关文献

参考文献10

  • 1Basmadjian- Charles CL, Farge P, Bourgeois DM,et al. Factors influencing the long - term results of endodontic treatment : a review of the literature [ J ]. Int Dent J,2002,52 (2) :81- 86.
  • 2Boucher Y, Matossian L, Rilliard F, et al. Radiographic evaluation of the prevalence and technical quality of root canal treatment in a French subpopulation [ J ]. Int Endodon J, 2002,35 (3) :229 -238.
  • 3范伟,范兵,陈智.管长度电测法的原理及其临床应用[J].口腔材料器械杂志,2002,11(4):195-197. 被引量:18
  • 4Huang L. An experimental study of the principle of electronic root canal measurement [ J ]. J Endodon, 1 987,1 3 (2) :60 - 64.
  • 5Fouad AF, Kre11 KV, Mckendry D J, et al. A clinical evaluation of five electronic root canal length measuring instrument [ J ]. J Endodon, 1990,16 (9) :446 - 449.
  • 6Lauper R, Lutz F, Barbakow F. An in vivo comparison of gradient and absolute impedance electronic apex locators [ J ]. J End- odon, 1996.22 (5) :260 - 263.
  • 7Frank AL, Torabinejad M. An in vivo evaluation of endex electronic apex locator [ J ]. J Endodon, 1993,19 (4) : 177 - 179.
  • 8Dunlap CA, Remeikis NA , BeGole EA, et al. An in vivo evaluation of an electronic apex locator that uses the ratio method in vital and necrotic canals [ J ]. J Endodon, 1998,24 ( 1 ) :48 - 50.
  • 9张雪峰,刘洪臣,刘荣森.根管治疗仪测定老年人磨牙根管工作长度准确性的初步研究[J].中华老年口腔医学杂志,2005,3(2):65-67. 被引量:9
  • 10Kobayashi C. Electronic canal length measurement [ J ]. Oral Sur Oral Med Oral Path, 1995,79 ( 2 ) : 226 - 231.

二级参考文献24

  • 1[4]Basmadjian-Charles C1,Farge P,Bourgeois DM,et al.Factors influencing helong-term results of endodontic treatment:a review of the literature[J].Int Dent,2002,52:81~86
  • 2[5]Boucher Y,Matossian L,Rilliard F,et al. Radiographic evaluation of the prevalence and technical quality of root canal treatment in a French subpopulation[J].Int Endod J,2002,52:81~86
  • 3[6]Kirkevang LL,Orstavik D,Horsted-Bindslev P,et al.Periapical status and quality of root filling and coronal restorations in a Danish population[J].Int Endod J,2000,33:509~515
  • 4[7]Huang,L、An experimental study of the principle of electronic root canal measurement [J].J-Endod, 1987,13(2):60~64
  • 5[8]Frank,A-L;Torabinejad,-M、An in vivo evaluation of Endex electronic apex locator [J].J-Endod.1993,19(4):177~179
  • 6Pratten Don H. , McDonald NJ. Comparison of Radiographic And Electronic Working Lengths. J Endodon, 1996,22(4): 173~176.
  • 7Kovacevic M. , Tamarut T. Inffuence of the concentration of Ions And Foramen Diameter on the Accuracy of Electronic Root Canal Length Measurement-an Experimental Study, J Endodon, 1998,24(5):346~351.
  • 8Pilot TF. , Pitts DL. Detemination of Impedance Changes at Varying Frequencies in Relation to Root Canal File Position and Irrigant. J Endodon, 1997,23(12) :719~724.
  • 9Vajrabhaya L. , Tepmorgkol P. Accuracy of Apex Locator. Endod.Dent. Traunatol, 1997, 13(4): 180~182.
  • 10Kobayashi C. , Suda H. New Electronic Canal Measuring Device Based on the Ratio Method. J Endodn, 1994,20(3):111~114.