摘要
建立了测定松针样品中多溴联苯醚(PBDEs)的分析方法。松针样品经过正己烷.丙酮(体积比为1:1)混合溶液超声萃取、浓硫酸和氧化铝柱净化后,采用气相色谱-负化学电离源质谱(GC—NCI—MS)选择离子监测(SIM)模式检测,内标法定量。结果表明,方法的加标回收率为83.8%~107.5%,三溴-七溴代联苯醚的仪器检出限为0.152~0.770pg,十溴代联苯醚(BDE-209)的检出限为11.1pg;三溴-七溴代联苯醚的方法检出限(湿重)为3~15pg/g,BDE-209的方法检出限(湿重)为222pg/g。方法具有良好的重现性、较高的灵敏度和良好的回收率。实际样品分析表明,松针中BDE-209是主要的同类物,约占8种PBDEs总量的82.3%,低溴代联苯醚以2,2’,4,4’-四溴联苯醚(BDE-47)为主。
A method for the determination of polybrominated diphenyl ethers (PBDEs) in pine needles was developed. Ultrasonic-assisted extraction (UAE) was employed with n-hexane-acetone (1: 1, v/v), and concentrated H2SO4 and an alumina column were used for cleaning-up the extract of pine needles. The final extract was identified and quantified for the 8 PBDE congeners (BDE-28, 47, 99, 100, 153, 154, 183, and 209) by gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS) with internal standard method in the selective ion monitoring (SIM) mode. The recoveries of the spiked standards ranged from 83.8% to 107.5%. The instrumental detection limits for tri- to hepta-BDEs (BDE-28, 47, 99, 100, 153, 154 and 183) were in the range of 0. 152 -0.770 pg, and for BDE-209 was 11. 1 pg. The method detection limits for the above-mentioned PBDEs were 3 - 15 pg/g wet weight and 222 pg/g wet weight, respectively. The results indicate that the me.thod has high sensitivity, satisfactory recovery and good repro- ducibility. BDE-209 was found to be the dominant congener (82.3% of the total of 8 PBDEs), and BDE-47 was the major congener among the lower brominated congeners.
出处
《色谱》
CAS
CSCD
北大核心
2009年第1期59-62,共4页
Chinese Journal of Chromatography
基金
国家重点基础研究计划("973"计划)课题(2006CB403302)
关键词
超声辅助萃取
气相色谱-负化学电离源质谱
多溴联苯醚
松针
ultrasonic-assisted extraction (UAE)
gas chromatography-negative chemical ionization-mass spectrometry (GC-NCI-MS)
polybrominated diphenyl ethers (PBDEs)
pine needles