摘要
输电线路导、地线接续管补强接续条可以对线路的接续管进行补强,接续管补强接续条在输电线路的维护、抢修时,可方便、快捷地对接续管故障点进行补修。为验证其技术性能,对JL-400/35B型接续管补强接续条进行了握力试验、直流电阻试验、温升试验和电晕试验,试验数据均满足国家标准要求。
Conductor and ground wire splicing reinforcing bar can reinforce splice sleeves. During line maintenance and emergency repair, it can be used to fix the point of splice sleeve failure conveniently and quickly. To verify its technical performance, grip strength test, DC resistance test, temperature rise test, and corona test are performed on JL-400/35B splicing reinforcing bars. All the test data meet national standards.
出处
《电力建设》
2009年第5期91-93,共3页
Electric Power Construction
关键词
导
地线
接续管补强接续条
握力试验
conductor and ground wire
splicing reinforcing bar
grip strength test