摘要
分析了空调系统相关设备动态模型的建立方法。结合实例,评价了土壤源热泵的能耗情况。能耗主要源自地埋管换热器循环泵,地下水位对土壤源热泵的能耗影响较大。
The establishment methods of dynamic models of relevant equipment of air conditioning system are analyzed. The energy consumption of ground-source heat pump is evaluated with an example. The energy consumption is mainly derived from circulating pump for buried tube heat exchanger, and the underground water level has significant effect on the energy consumption of ground-source heat pump.
出处
《煤气与热力》
2009年第5期10-12,共3页
Gas & Heat
基金
广东省科技计划项目(2007B080701002)
仲恺农业工程学院引进优秀人才科研启动基金(G2360246)
关键词
土壤源热泵
动态模型
能耗分析
ground-source heat pump
dynamic model
energy consumption analysis