期刊文献+

硬膜外罗哌卡因用于剖腹产术后镇痛的最低运动阻滞浓度 被引量:11

The minimal local analgesic concentration of epidural ropivacaine for cesarean patients
在线阅读 下载PDF
导出
摘要 目的研究剖腹产术后硬膜外镇痛的罗哌卡因最低运动阻滞浓度。方法30例ASAI级的择期剖腹产病人,采用上下序贯法用不同浓度罗哌卡因行硬膜外镇痛,术后12和24h评价镇痛效果和运动阻滞情况。结果罗哌卡因的最低运动阻滞浓度MMLAC为0.301%(95%可信区间0.280%~0.334%)。结论罗哌卡因用于剖腹产术后镇痛的最低运动阻滞浓度为0.301%。 Objective To determine the motor block minimal local analgesic concentration (MMLAC) of epidural ropivacaine for cesarean patients. Methods MMLAC, defined as the 50 % effective concentration (ECS0) of femoral articulation blockade, was determined by up-and-down sequential method in 30 patients undergoing selective cesarean. Result MMLAC of epidural ropivacaine estimated in this study was 0. 301% with a 95% confidence interval of 0. 280% to 0. 334 %. Conclusion There is a range of epidural ropivacaine concentraion to produce satisfactory analgesia with little motor block and the result of this study can help to choose a proper ropivacaine concentration for cesarean patients
出处 《实用临床医药杂志》 CAS 2009年第5期40-41,共2页 Journal of Clinical Medicine in Practice
  • 相关文献

参考文献7

二级参考文献18

  • 1朱波,徐建青,叶铁虎,任洪智,黄宇光,罗爱伦.腹式子宫切除术后甲磺酸罗哌卡因与盐酸罗哌卡因硬膜外病人自控镇痛的比较[J].中华麻醉学杂志,2005,25(8):572-575. 被引量:42
  • 2徐建青,朱波,叶铁虎,吴新民,秦翔,王庚,许幸,于布为,李一亮,周静芳,王玉萍.手术患者0.894%甲磺酸罗哌卡因与0.75%盐酸罗哌卡因硬膜外麻醉的效果[J].中华麻醉学杂志,2005,25(8):624-625. 被引量:48
  • 3Markham A, Faulds D. Ropivacaine: a review of its pharmacology and therapeutic use in regional anaesthesia. Drugs, 1996, 52: 429-449.
  • 4Columb MO, Lyons G. Determination of the minimum local analgesic concentrations of epidural bupivacaine and lidocaine in labor. Anesth Analg, 1995, 81:833-837.
  • 5Capogna G, Celleno D, Fusco P, et al. Relative potencies of bupivacaine and ropiacaine for analgesia in labor. Br J Anaesth, 1999, 82:271-273.
  • 6Bromage PR. Epidural analgesia. 1st ed. Philadelphia: WB Saunders,1978.144.
  • 7Dixon WJ, Massey FJ. Introduction to statistical analysis, 4th ed. New York: Mcgraw-Hill, 1983.319-327.
  • 8Polley LS, Columb MO, Wagner DS, et al. Dose-dependent reduction of the minimal local analgesic concentration of bupivacaine by sufentanil for epidural analgesia in labor. Anesthesiology, 1998, 89:626-632.
  • 9Lacassie HJ , Columb MO, Lacassie HP, et al. The relative motor blocking potencies of epidural bupivacaine and ropivacaine in Labor.Anesth Analg,2002,95: 204-208.
  • 10Polley LS, Columb MO, Naughton NN, et al. Relatvie analgesic potencies of ropivacaine and bupivacaine for epidural analgesia in labor:implications for therapeutic indexes. Anesthesiology, 1999, 90:944-950.

共引文献71

同被引文献76

引证文献11

二级引证文献118

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部