期刊文献+

8-14μm波段红外烟幕透过率的测试与修正(英文) 被引量:1

Correction and Measurement of Transmittance of Smoke in 8-14 μm Waveband
在线阅读 下载PDF
导出
摘要 为了减少烟幕温度对8-14μm波段烟幕透过率的影响,分析了有红外辐射源和没有红外辐射源的燃烧型红外烟幕的透过率。结果发现两种情况下5 g发烟剂被点燃后的透过率分别是40%-50%和15%-20%,燃烧形成的红外烟幕导致烟幕云团具有很强的红外辐射。为此提出了减差修正法,烟幕的透过率通过减去没有红外辐射源时的透过率得到修正,5 g发烟剂的透过率减小为25%-35%。 To reduce the effects of smoke temperature on the transmittance measurement in 8 - 14 μm waveband, the transmittanees of infrared smoke was analyzed with and without infrared radiation source. Results show that the transmittanees of 5 g smoke agent is 40% -50% and 15% -20%. And the infrared smoke formed by burning leads to smoke cloud with a strong radiation. Then, a different correcting method was carried out. The transmittance is corrected by subtracting from the transmittance of infrared smoke without infrared radiation source, and transmittance of the smoke agent with infrared radiation source decrease to 25% -35%.
出处 《含能材料》 EI CAS CSCD 北大核心 2009年第4期482-485,共4页 Chinese Journal of Energetic Materials
关键词 红外物理 烟幕 辐射 透过率 infrared physics smoke radiation transmittance
  • 相关文献

参考文献5

二级参考文献18

  • 1朱晨光,潘功配,关华,周遵宁.红外烟幕遮蔽率测试方法研究[J].红外技术,2004,26(4):81-84. 被引量:19
  • 2李明 ,范东启 ,康文运 ,王云萍 ,殷纯永 .外场用烟幕遮蔽效果测量系统[J].飞行器测控学报,2005,24(4):76-80. 被引量:2
  • 3杨宜禾 周维真.成像跟踪技术导论[M].西安:西安电子科技大学出版社,1991.149-154.
  • 4[1]AD-B031193[R
  • 5[2]Englinedring design ham book[M], Military pyrotechenics series Part ore 1967
  • 6[5]顾国华.光辐射测试技术[M].上海:华东工学院出版社,1987
  • 7Gerald C. Infrared transmission measurements through smoke screen: experimental considerations[R]. AD-A090404.
  • 8唐宏志.烟幕干扰与红外效能测试方法[C]..中国兵工学会第十一届火工烟火技术年会[C].,2001.312-319.
  • 9AD-B031193 Methodology Investigation for Testing Eeffectiveness of Smoke/Aerosol [ R].1980.
  • 10Vakin S,Shustov L,Dunwell R.Fundamentals of electronic warfare[M].Boston:Artech House,2001:111-166.

共引文献38

同被引文献32

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部