期刊文献+

利用密度反馈实现离子源长脉冲放电 被引量:13

Long pulse ion source discharge based on plasma density feedback
在线阅读 下载PDF
导出
摘要 介绍了等离子体密度对离子源放电的影响,为了获得长脉冲放电,采用朗缪尔探针测量等离子体密度并反馈调节离子源放电。基于朗缪尔探针测量,设计了控制部分硬件与软件构架,建立了离子源等离子体密度反馈控制系统,并成功地应用于离子源等离子体放电实验,通过反馈调节实验进气,得到了长达4.5 s的长脉冲放电,为中性束注入稳态运行提供了依据。 The influence of plasma density on plasma discharge has been introduced. In order to obtain the long pulse discharge, the Langmuir probe was employed to measure the plasma density and to control the plasma discharge with feedback. The hardware and software of the control parts were designed and the plasma density feedback control system was established based on the Langmuir probe measurement. Besides, the system was applied to the ion source plasma discharge experiment successfully. The long pulse discharge of 4.5 s was got and it provides the fundamental for the steady-state operation of neutral beam injection in the future.
作者 刘胜 胡纯栋
出处 《强激光与粒子束》 EI CAS CSCD 北大核心 2009年第9期1331-1334,共4页 High Power Laser and Particle Beams
基金 国家自然科学基金项目(10875146)
关键词 离子源 朗缪尔探针 密度反馈控制 长脉冲放电 ion source Langmuir probe density feedback control long pulse discharge
  • 相关文献

参考文献7

二级参考文献25

共引文献17

同被引文献109

  • 1盛鹏,胡纯栋,刘胜,宋士花,谢亚红.实时反馈控制在离子源放电实验中的应用[J].核技术,2007,30(6):537-542. 被引量:3
  • 2张海兵,阮林波,李斌,冯兵.利用光纤收发器实现远程高速数据采集[J].光通信技术,2006,30(1):44-45. 被引量:6
  • 3胡立群,张晓东,姚若河.EAST托卡马克的中性束注入方案[J].核技术,2006,29(2):149-152. 被引量:17
  • 4倪康婷,王毅,常广.一种光纤隔离的电压变送器设计[J].自动化博览,2006,23(1):77-78. 被引量:1
  • 5Praeg W F.Overcurrent protection for the TFTR neutral beam sources during spark down[C] //The 8th Symposium on Engineering Problems of Fusion Research.1979:1260-1266.
  • 6Watanabe K,Mizuno M,Nakajma S,et al.Development of a high performance core Snubber for high power neutral beam injectors[J].Review of Scientific Instruments,1998,69(12):4136-4141.
  • 7Bishop S R,Mayhall D J,Wilson J H,et al.Design and test of 80 kV Snubber core assemblies for MFTF sustaining neutral beam power supplies[C] //The 9th Symposium on Engineering Problems of Fusion Research.1981:419-422.
  • 8Bishop J E L.Eddy-current-limited growth of ferromagnetic domains on the surface of square-loop alloy tapes[J].J Phys D,1976,(9):2095-2110.
  • 9Winter S D,Kuenning R W,Berg G G.Pulse properties of large 50-50 NiFe tape cores[J].IEEE Trans on Magn,1970,6(1):41-45.
  • 10Williams H J,Schockley W,Kittle C.Studies of the propagation velocity of a ferromagnetic domain boundary[J].Phys Rev,1950,80(6):1090-1094.

引证文献13

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部