期刊文献+

青光眼房水引流装置植入手术 被引量:6

原文传递
导出
摘要 难治性青光眼的治疗一直是眼科临床工作中的棘手问题之一,常规小梁切除术后滤过道易于瘢痕化,难以建立有效的房水滤过通道,手术成功率较低。1969年Molteno发明了青光眼房水引流装置植入术并应用于难治性青光眼的治疗,以此为基础经过不断地完善,一些新型的现代前房引流装置不断问世。
出处 《中华眼科杂志》 CAS CSCD 北大核心 2009年第10期957-960,共4页 Chinese Journal of Ophthalmology
  • 相关文献

参考文献22

  • 1Molteno AC. New implant for drainage in glaucoma:clinical triM. Br J Ophthalmol, 1969,53:606-615.
  • 2Lloyd MA, Sedlak T, Heuer DK, et al. Clinical experience with the single-plate Molteno implant in complicated glaueomas:update of a pilot study. Ophthalmology, 1992, 99:679-687.
  • 3Melamed S. Molteno implant surgery in refractory glaucoma. Surv Ophthalmol, 1990,68 : 879 -883.
  • 4Prata JA, Mermoude A, Labree L, et al. In vitro and in vivo flow characteristics of glaucoma drainage implants. Ophthalmology, 1995,102:894-904.
  • 5Taglia DP, Perkins TW, Gangnon R, et al. Comparison of the Ahmed glaucoma valve, the krupin eye valve with disk, and the double-plate Molteno implant. J Glaucoma,2002,11:347-353.
  • 6Barton K, Heuer DK. Modem aqueous shunt implantation:future challenges. Prog Brain Res ,2008,173:263-276.
  • 7Kee C. Prevention of early postoperative hypotony by partial ligation of silicone tube in Ahmed glaucoma valve implantation. J Glaucoma,2001,10:466-469.
  • 8Yalvac IS, Eksioglu U, Satana B, et al. Long-term results of Ahmeq glaucoma valve and Molteno implant in neovascular glaucoma. Eye, 2007,21:65-70.
  • 9Souza C,Tran DH, Loman J, et al. Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas. Am J Ophthalmol,2007,144 : 893-900.
  • 10Mermoud A, Salmon JF, Alexander P, et al. Moheno tube implantation for neovascular glaucoma: long-term results and factors influencing the outcome. Ophthalmology, 1993,100 : 897- 902.

二级参考文献15

  • 1林明楷,葛坚,卓业鸿,凌云兰,王梅,林羡钗,黄圣松.异体巩膜瓣联合引流管植入治疗难治性青光眼[J].中华显微外科杂志,2006,29(6):463-465. 被引量:25
  • 2朱家恺 庞水发.把我国显微外科推向21世纪新里程[J].中华显微外科杂志,2000,23(1):5-7.
  • 3Taglia DP, Perkins TW, Gangnon R, et al. Comparison of the Ahmed Glaucoma Valve, the Krupin Eye Valve with Disk, and the double-plate Molteno implant. J Glaucoma, 2002,11 : 347 - 353.
  • 4Kee C. Prevention of early postoperative hypotony by partial ligation of silicone tube in Ahmed glaucoma valve implantation. J Glaucoma, 2001 10:466 - 469.
  • 5Perkins TW, Gangnon R, Ladd W, et al. Moheno implant with mitomycin C: intermediate-term results. J Glaucoma, 1998,7:86 - 92.
  • 6Kurnaz E, Kubaloglu A, Yilmaz Y, et al. The effect of adjunctive Mitomycin C in Ahmed glaucoma valve implantation. Eur J Ophthalmol, 2005,15:27 - 31.
  • 7Costa VP, Azuara-Blanco A, Netland PA, et al. Efficacy and safety of adjunctive mitomycin C during Ahmed Glaucoma Valve implantation: a prospective randomized clinical trial. Ophthalmology, 2004, 111 : 1071 - 1076.
  • 8Trigler L, Proia AD, Freedman SF. Fibrovascular ingrowth as a cause of Ahmed glaucoma valve failure in children. Am J Ophthalmol, 2006,141:388 - 389.
  • 9Yalvac IS, Eksioglu U, Satana B, et al. Long-term results of Ahmed glaucoma valve and Moheno implant in neovas cular glaucoma. Eye, 2007,21:65 - 70.
  • 10Tsai JC, Johnson CC, Dietrich MS. The Ahmed shunt versus the Baerveldt shunt for refractory glaucoma: a single-surgeon comparison of outcome. Ophthalmology, 2003, 110:1814 -1821.

共引文献34

同被引文献34

引证文献6

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部