期刊文献+

种植体形态结构设计研究进展 被引量:6

在线阅读 下载PDF
导出
摘要 种植体的稳定性对种植体成功率至关重要,除了宿主因素和医源因素外,影响初期稳定性的关键是种植体的设计。种植体外形、长度、直径及表面处理都会影响种植的成功率。笔者就种植体表面结构、长度、直径等设计因素之间的关系进行综述。
出处 《广东牙病防治》 2009年第11期560-565,共6页 Journal of Dental Prevention and Treatment
  • 相关文献

参考文献46

  • 1Branemark PI, Adell R, Breine U, et al. Intra-osseous anchorage of dental prostheses. Ⅰ. Experimental studies. Scand J Plast Reconstr Surg, 1969,3(2) :81-100.
  • 2Adell R, Hansson BO, Bramemark PI, et al. Intra-osseous anchorage of dental prostheses. Ⅱ. Review of clinical approaches. Scand J Plast Reconstr Surg, 1970,4 ( 1 ) : 19-34.
  • 3Misch CE. Contemporary implant dentistry. 2nd ed. St. Louis: Elsevier, 1999:54.
  • 4Miloro M. Peterson's principles of oral and maxillofacial surgery. 2nd ed. London: BC Decker Inc, 2004:255.
  • 5Renouard F, Nisand D. Impact of implant length and diameter on survival rates. Clin Oral Implants Res, 2006,17 (Suppl 2) :35-51.
  • 6Ivanoff C J, Sennerby L, Johansson C, et al. Influence of implant diameters on the integration of screw implants. An experimental study in rabbits. Int J Oral Maxillofae Surg, 1997,26(2) :141-148.
  • 7Langer B, Langer L, Herrmann I, et al. The wide fixture: a solution for special bone situations and a rescue for the compromised implant. Part 1. Int J Oral Maxillofac Implants, 1993,8(4) :400-408.
  • 8Ettinger RL, Spivey JD, Han DH, et al. Measurement of the interface between bone and immediate endosseous implants: a pilot study in dogs. Int J Oral Maxillofac hnplants, 1993,8 (4) :420-427.
  • 9Hahn P, Schaller H, Hafner P, et al. Effect of different luting procedures on the seating of ceramic inlays. J Oral Rehabil, 2000,27 (1) :1-8.
  • 10El Zohairy AA, De Gee AJ, Mohson MM ,et al. Microtensile bond strength testing of luting cements to prefabricated CAD/CAM ceramic and composite blocks. Dent Mater, 2003,19 (7) :575-583.

二级参考文献13

  • 1Cehreli M,Duyck J,De Cooman M,et al.Implant design and interface force transfer.A photoelastic and strain-gauge analysis[J].Clin Oral Implants Res,2004,15(2):249-257.
  • 2Ivanoff C J,Grondahl K,Sennerby L,et al.Influence of variations in implant diameters:A 3-to 5-year retrospective clinical report[J].Int J Oral Maxillofac Implants,1999,14(2):173-180.
  • 3Brunski JB.Biomechanical considerations in dental implant design[J].Int J Oral Implantol,1988,5(1):31-34
  • 4Timoshenko SP,Goodier JN.Theory of elasticity[M].Singapore:McGraw-Hill International Book Co.,1984:15-40.
  • 5Zienkiewicz OC.The finite element method in engineering science[M].4th ed.New York:McGraw-Hill International Book Co.,1989:100-120.
  • 6Kitamura E,Stegaroiu R,Nomura S,et al.Biomechanical aspects of marginal bone resorption around osseointegrated implants:Considerations based on a three-dimensional finite element analysis[J].Clin Oral Implants Res,2004,15(4):401-412.
  • 7Cook SD,Klawitter JJ,Weinstein AM.A model for the implantbone interface characteristics of porous dental implants[J].J Dent Res,1982,61(8):1006-1009.
  • 8Borchers L,Reichart P.Three-dimensional stress distribution around a dental implant at different stages of interface development[J].J Dent Res,1983,62(2):155-159.
  • 9Colling EW.The physical metallurgy of titanium alloys[M].American Society for Metals,Ohio:Metals Park,1984:53-78.
  • 10Lewinstein I,Banks-Sills L,Eliasi R.Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis[J].Int J Oral Maxillofac Implants,1995,10 (3):355-366.

共引文献22

同被引文献69

引证文献6

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部