摘要
从阀控铅蓄电池的根本特点出发,分析一些最常见的故障(如热失控、失水)出现的原因及其克服方法;同时利用统计数字的原理和方法进一步对通信电源系统中的检测和控制技术提出一些改进意见和看法,以期延长蓄电池使用寿命,早期诊断和预防蓄电池可能出现的故障,并确保通信电源系统具有很好的可靠性。
The reason and surmountable technique of some failures ap-peared frequently such as thermal runaway and water loss in VRLAB wereanalysed in view of the specific property of this battery, and some improv-ing desires and concepts about the VRLAB test and maintenance in com-munication power source system were put forward based on the statisticalmathematical principle and technique, in order to prolong the service life,diagnose and prevent the potencial failures in advance, ensuring the relia-bility of communication power source system.
出处
《蓄电池》
1998年第3期28-33,共6页
Chinese LABAT Man
关键词
铅酸蓄电池
检测
维护
阀控式蓄电池
通信电源
communication power source, power source system, battery, reliability