突然断线对输电塔线体系的冲击作用研究 被引量:28

Research of impact effect on transmission line systemdue to sudden breakage of conductor
在线阅读 下载PDF
导出
摘要 突然断线使处于绷紧状态的输电线张力迅速释放,塔线体系将受到动力冲击作用,但设计规范仅按静态荷载来考虑断线荷载。以某输电线路为例,采用有限元方法建立塔线体系模型,进行断一根至六根子导线工况的模拟,并考虑跌落导线与地面的碰撞。分析发现,断子导线的根数越多,或者越接近断线点,直线塔绝缘子的摆动幅度越大,峰值轴力也越大。导线断线将产生两个极大的冲击作用,一个是导线断裂产生的冲击,另一个是跌落导线与地面碰撞产生的冲击。 The sudden breakage of conductor enables the quick release of tension in conductor,which causes the dynamic impact effect on transmission line system.However,the design codes of transmission towers usually consider conductor breakage load as static load.Taking a transmission line system as example,finite element method was employed to construct the tower-line model.In calculation,the cases of one sub-conductor breakage to six sub-conductors breakage were simulated and the impinging of dropping conductors against ground was considered.The conclusions show that the bigger the number of broken sub-conductors is or the closer the broken point is to the insulator,the larger the swing amplitudes and the peak axial forces on insulators of tangent towers will be.The breakage of conductors will result in two major impacts: the one is induced directly by the sudden breakage of conductors and the other is induced by impinging of dropping conductors against ground.
出处 《振动与冲击》 EI CSCD 北大核心 2009年第12期4-8,共5页 Journal of Vibration and Shock
基金 国家自然科学基金资助项目(50638010) 浙江省自然基金资助项目(Y1080207)
关键词 输电塔 绝缘子 有限元 断线荷载 冲击作用 transmission line insulator finite element method conductor breakage load impact effect
  • 相关文献

参考文献15

  • 1Bob Oswald, Dennis Schroeder, Peter Catchpole. Investigative summery of the July 1993 Nebraska Public District Grand Island-Moore 345kV transmission line failure[ C] , Transmission and Distribution Conference, Proceedings of the 1994 IEEE Power Engineering Society, 1994,574 -580.
  • 2DL/T5092-1999 110-500kV架空送电线路设计技术规程[S].北京:中国电力出版社,1999.
  • 3DIJT5154-2002,架空送电线路杆塔结构设计技术规定[S].北京:中国电力出版社,2002.
  • 4David B. Campbell. Unbalanced tensions in transmission lines [ J ]. Journal of the Structural Division, Proceeding of American Society of Civil Engineering, 1970, 96(ST10) :2189 - 2207.
  • 5John D. Mozer, Joe C. Pohlman, John F. Fleming. Longitudinal load analysis of transmission line systems [ J ]. IEEE Transactions on Power Apparatus and System, 1977, PAS - 96(5) :1657 - 1664.
  • 6Thomas M B, Peyrot A H. Dynamic response of ruptured conductors in transmission lines [ J ]. IEEE Transactions on Power Apparatus and System, 1982, PAS - 101 (9) : 3022 - 3027.
  • 7Faruq M A Siddiqui, John F. Fleming. Broken wire analysis of transmission line systems [ J ]. Computer and Structures, 1984, 18(6) :1077 - 1085.
  • 8McClure G, Tinawi R. Mathematical Modeling of the transient response of electric transmission lines due to conductor breakage[J]. Computer and Structures, 1987, 26(1/2) :41 -56.
  • 9McClure G, Lapointe M. Modeling the structural dynamic response of overhead transmission lines [ J ]. Computer and Structures, 2003, 81:825 - 834.
  • 10夏正春,李黎,梁政平,段松涛.输电塔在线路断线作用下的动力响应[J].振动与冲击,2007,26(11):45-49. 被引量:37

二级参考文献29

共引文献84

同被引文献293

引证文献28

二级引证文献88

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部