期刊文献+

水质条件对氧传质影响的研究 被引量:22

Research on Impact of Water Quality on Oxygen Transition
在线阅读 下载PDF
导出
摘要 通过对不同条件下水体的曝气增氧实验,研究了温度、浊度以及pH对曝气水体中氧传质的影响.研究结果表明:氧总转移系数KLa随着温度的升高而增大,而氧转移速率υOTR的总体趋势是缓慢减小的,但在25℃附近υOTR有增大的趋势;在不同浊度的水体中,KLa和υOTR均随着水体浊度的增加而不断增大,与水体的浊度呈明显的正相关关系;水体pH对KLa和υOTR也有一定的影响,随着pH的增加,KLa和υOTR均是先降低后增加,并在pH为7.0时达到最小值. Effects of temperature, turbidity and pH on oxygen transition in aerated water under different conditions were studied. The results showed that the oxygen transfer coefficient (KLa) increased with the increasing temperature, while the oxygen transfer rate (VOTR) decreased except with an increasing tendency at around 25 ℃. In turbid water, KLaand uOTRare positively correlated to the level of turbidity. The pH value can also influence KLa and VOTR at certain degree. As the pH value was increased, KLa and vOTR firstly decreased and then increased, and had minimum values at pH 7.0.
出处 《中北大学学报(自然科学版)》 CAS 北大核心 2010年第1期45-49,共5页 Journal of North University of China(Natural Science Edition)
基金 国家高技术研究发展资助项目(863计划)(2005AA60101005 2007AA06Z347) 国家自然科学基金资助项目(20677038) 上海市科委创新行动计划资助项目(072312002)
关键词 温度 浊度 PH 氧传质系数 氧转移速率 temperature turbidity pH oxygen transfer coefficient oxygen transfer rate
  • 相关文献

参考文献12

  • 1Rosso D, Stenstrom M K. Surfactant effects on a-factors in aeration systems [J]. Water Research, 2006, 40: 1397- 1404.
  • 2孙从军,张明旭.河道曝气技术在河流污染治理中的应用[J].环境保护,2001,29(4):12-14. 被引量:176
  • 3Mahendraker V, Mavinic D S, Hall K J. Comparison of oxygen transfer parameters determined from the steady state oxygen uptake rate and the non-steady-state changing power level methods [J]. Journal of Environmental Engineering, 2005(5): 692-701.
  • 4Leu H G, Lin S H, Shyu C C, et al. Effects of surfactants and suspended solids on oxygen transfer under various operating conditions[J]. Environ. Technol. , 1998, 19: 299-306.
  • 5Vogelaar J C T, Klapwijk A, Van Lier J B, et al. Temperature effects on the oxygen transfer rate between 20 ℃ and 55 ℃[J]. Wat. Res. , 2000, 34(3): 1037-1041.
  • 6汤利华,孟广耀.水深对曝气过程中氧总转移系数的影响[J].同济大学学报(自然科学版),2007,35(6):760-763. 被引量:20
  • 7赵静野,郑晓萌,高军.曝气充氧中氧总传质系数的探讨[J].北京建筑工程学院学报,2006,22(1):11-13. 被引量:20
  • 8孙从军,陈季华.水温对氧转移速率的影响研究[J].环境科学研究,1998,11(4):13-15. 被引量:17
  • 9Vogelaar J C T, Klapwijk A, Van Lier J B, et al. Temperature effects on the oxygen transfer rate between 20 C and 55 C[J]. Water Research, 2000, 34(2): 1037-1041.
  • 10Boogerd F C, Bos P, Kuenen J G, et al. Oxygen and carbon dioxide mass transfer and the aerobic, autotrophic cultivation of moderate and extreme thermophiles : a case study related to the microbial desulphurization of coal[J]. Biotechnol. Bioeng. , 1990, 35: 1111-1119.

二级参考文献15

  • 1刘延恺,陆苏,孟振全.河道曝气法——适合我国国情的环境污水处理工艺[J].环境污染与防治,1994,16(1):22-25. 被引量:66
  • 2Viadimir Novotny 俞亚明译.Karl Imhoff城市排水与污染处理手册[M].北京:中国建筑工业出版社,1992..
  • 3Barboza M,Zaiat M,Hokka C O.General relationship for volumetric oxygen transfer coefficient (KLa) prediction in tower bioreactors utilizing immobilized cells[J].Bioprocess and Biosystems Engineering,2000,22(2):181.
  • 4北京市政工程设计研究总院.给水排水设计手册:第5册[M].2版.北京:中国建筑工业出版社,2004.
  • 5Vilaca P R,Badino Jr A C,Facciotti M C R,et al.Determination of power consumption and volumetric oxygen transfer coefficient in bioreactors[J].Bioprocess and Biosystems Engineering,2000,22(3):261.
  • 6傅献彩,沈文霞,姚天扬.物理化学[M].4版.北京:高等教育出版社,2004.
  • 7中国市政工程华北设计研究院.给水排水设计手册:第12册[M].2版.北京:中国建筑工业出版社,2001.
  • 8德金七博(KinelbachW·) 著杨汝均等 编纂水环境数学模型[M].
  • 9孙从军,陈季华.水温对氧转移速率的影响研究[J].环境科学研究,1998,11(4):13-15. 被引量:17
  • 10王诚信,凌晖,史可红.污染河流的纯氧曝气复氧[J].上海环境科学,1999,18(9):411-413. 被引量:31