冷却塔容量选择对地源热泵空调系统能耗影响 被引量:1

Effect of Cooling Tower Capacity Selection on Energy Consumption of Ground Source Heat Pump Air Conditioning System
在线阅读 下载PDF
导出
摘要 对于以冷负荷为主导的建筑,采用冷却塔辅助散热复合式地源热泵一方面能调节地下散热的平衡,另一方面减少了系统的初投资,但同时增加了冷却塔水泵和风机的功耗。文中从地源热泵的动态模型入手,模拟了不同冷却塔容量选型时系统能耗情况。模拟结果表明,合理的冷却塔选型具有较大的节能潜力。 For cooling load-oriented architecture, the use of cooling tower in ground-source heat pump air conditioning system can not only adjust the thermal balance of the underground, but also reduce the system's initial investment. On the contrary, it increases the pump and cooling tower's power consumption. The system energy consumption for different cooling tower capacity selection based on the thermal dynamic model of hybrid ground-source heat pump system was simulated. The results show that there is an obvious energy-saving potential for a reasonable selections of cooling tower capacity.
出处 《建筑热能通风空调》 2010年第1期60-63,共4页 Building Energy & Environment
关键词 冷却塔 复合式地源热泵 动态模型 cooling tower, hybrid ground-source heat pump, dynamic model
  • 相关文献

参考文献4

  • 1简毅文.模拟软件DeST的可应用性分析[J].北京工业大学学报,2007,33(1):46-50. 被引量:17
  • 2Hamilton J M,J L Miller.A simulation program for modeling an air-conditioning system[J].ASHRAE Transactions,1990,96(1):213-221.
  • 3Ingersoll L R,H J Plass.Theory of the ground pipe heat source for the heat pump[J].ASHRAE Transactions,1948,47:339-348.
  • 4Yavuzturk C,J D Spiltler.Comparative study to investigate operating and control strategies for hybrid ground source heat pmp systems using a short time-step simulation model[J].ASHRAE Transactions,2000,106(2):192-209.

二级参考文献8

  • 1张晓亮,谢晓娜,燕达,江亿.建筑环境设计模拟分析软件DeST 第3讲 建筑热环境动态模拟结果的验证[J].暖通空调,2004,34(9):37-50. 被引量:34
  • 2LOMAS K J,EPPLE H,MARTIN C,et al.Empirical validation of building energy simulation programs[J].Energy and Buildings,1997,26(3):253-275.
  • 3BLOOMFIELD D P.An overview of validation methods for energy and environmental software[J].ASHRAE Trans,1999,105(2):685-693.
  • 4RENE Meldem,FREDERICK Winkelmann.Comparison of DOE-2 with temperature measurements in the Pala test houses[J].Energyand Buildings,1998(27):69-81.
  • 5PAPAKOSTAS K T,SOTIROPOULOS B A.Occupational and energy behavior patterns in Greek residences[J].Energy and Buildings,1997,26(2):207-213.
  • 6IWASHITA G O,HIROSHI Akasaka.The effects of human behavior on natural ventilation rate and indoor air environment in summer:a field study in southern Japan[J].Energy and Buildings,1997,25(3):195-205.
  • 7JIANG Yi.State-space method for the calculation of air-conditioning loads and the simulation of thermal behavior of the room[J].ASHRAE Transactions,1982,88(2):122-141.
  • 8HONG Tian-zhen,JIANG Yi.New multizone model for the simulation of building thermal performance[J].Building and Environment,1997,32(2):123-128.

共引文献16

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部