期刊文献+

动态监测cystatin C对肾移植排斥反应的诊断价值

在线阅读 下载PDF
导出
摘要 目的研究动态监测血清半胱氨酸蛋白酶抑制剂C(cystatin C,Cys C)对肾移植排斥反应的诊断价值。方法36例肾移植患者,稳定组29例,排斥组7例,20例健康体检者作为对照组。对术后稳定组和排斥组的Cys C和Cr、Ure、UA进行术前、术后不同时间点的动态监测并测定术后肾小球滤过率(GFR)。结果移植术前,稳定组和排斥组的各项指标均显著高于对照组(P<0.01);稳定组Cys C、Cr、Ure从术后1 d起均显著低于术前水平(P<0.01)。Cys C下降最明显(42.9%),UA则从术后3 d起显著低于术前水平(P<0.01)。与稳定组比较,术后排斥组的Cys C、Cr、Ure、UA分别升高了120.0%、91.8%、93.8%和86.9%,且Cys C的变化最早发生;Cys C、Cr、Ure、UA与GFR均呈显著负相关(P<0.01),Cys C与GFR的相关系数(r=-0.935)最大;ROC曲线下面积(AUCROC)Cys C(0.933)明显优于其他指标(P<0.01)。结论Cys C能较其他指标更早期、灵敏地判断肾移植排斥反应。
出处 《临床检验杂志》 CAS CSCD 北大核心 2010年第3期192-193,共2页 Chinese Journal of Clinical Laboratory Science
基金 天津市卫生局科技基金项目(07KZ52)
  • 相关文献

参考文献3

二级参考文献13

  • 1Blaufox MD,Aurell M,Bubeck B,et al. Report of the radionuclides in nephrourology committee on renal clearance [ J ]. J Nucl Med,1996, 37: 1883 - 1890
  • 2Durand E, Prigent A. The basics of renal imaging and function studies[J]. Q J Nucl Med, 2002, 46:249 -267
  • 3Petersen LJ, Petersen JR, Talleruphuus U, et al. Glomerular filtration rate estimated from the uptake phase of 99 mTc-DTPA renography in chronic renal failure [ J ]. Nephrol Dial Transplant, 1999 , 14:1673 - 1678
  • 4Russell CD. Optimum sample times for single-injection, multisample renal clearance methods[ J]. J Nucl Med, 1993, 34:1761 - 1765
  • 5Itoh K,Tsushima S,Tsukamoto E, et al. Accuracy of plasma sample methods for determination of glomerular filtration rate with 99mTc-DTPA[J]. Ann Nucl Med, 2002, 16:39 -44
  • 6Waller DG, Keast CM, Fleming JS, et al. Measurement of Glomerular Filtration Rate with Technetium-99m DTPA: comparison of Plasma Clearance Techniques[J]. J Nucl Med, 1987, 28:372 -377
  • 7Piepsz A, Dobbeleir A, Erbsmann F. Measurement of separate kidney clearance by means of 99mTc-DTPA complex and a scinitillation camera[J]. Eur J Nucl Med, 1977, 2:173 - 177
  • 8Gates FG. Glomerular filtration rate: estimation from fractional renal accumulation of 99mTc-DTPA[ J]. Am J Roentgenol, 1982, 138:565- 570
  • 9Inoue Y, Ohtake T, Homma Y, et al. Evaluation of glomerular filtration rate by camera-based method in both children and adults [ J ].J Nucl Med, 1998,39: 1784-1788
  • 10Itoh K,Tsushima S,Tsukamoto E, et al. Reappraisal of single-sample and gamma camera methods for determination of the glomerular filtration rate with 99mTc-DTPA[J]. Ann Nucl Med, 2000, 14:143- 150