期刊文献+

Moria-M_2角膜板层刀90刀头在LASIK中的应用

Application of Knife 90 of Moria-M_2 in LASIK surgery
在线阅读 下载PDF
导出
摘要 目的:评价准分子激光原位角膜磨镶术(laser in situ keratomileusis,LASIK)中应用Moria-M2角膜板层刀90刀头制作角膜瓣的安全性、可预测性及可重复性。方法:分别观察我院90刀头组制作角膜瓣500例1000眼及130刀头组制作角膜瓣510例1010眼,比较两种刀头制作角膜瓣术中角膜瓣形态、角膜瓣厚度、角膜瓣直径、角膜瓣蒂长及相关并发症。结果:90刀头组角膜瓣厚度为90~120(平均105.5±15.5)μm,130刀头组角膜瓣厚度为130~160(平均145±15)μm,差异有显著的统计学意义。两种刀头制作的角膜瓣,其角膜瓣直径、角膜瓣蒂长、弧度、角膜瓣形态及其他角膜瓣制作相关的并发症均无显著差异。结论:Moria-M2角膜板层刀90刀头制作角膜瓣具有良好的安全性、可预测性和可重复性,切削面洁净平整,操作及维护简单。 AIM. To evaluate the safety, efficiency and repeatability of using the Knife 90 of Moria-M2 to make corneal flap in LASIK. METHODS: Five hundred cases 1000 eyes were performed by Knife 90 and 510 cases 1010 eyes were performed by Knife 130, and the shape, thickness, diameter, pedice length and complication of the corneal flap were observed and compared by two different knives. RESULTS: The thickness of corneal flap with 90 heads was 90-120μ m and the average was 105.5 ±15.51μm, but the thickness of corneal flap with 130 heads was130-160μm and the average was 145 ± 15μm. There was significantly statistical difference. There was no significantly statistical difference in corneal flap diameter, corneal flap pedicle length, curvature, shape and other complications with two different heads. CONCLUSION :It is very safe, efficient and repeatable to use the Knife 90 of Moria-M2 to make corneal flap, the surface of corneal flap are smooth and clean, and the Knife 90 is easy to operate and maintain.
出处 《国际眼科杂志》 CAS 2010年第7期1319-1320,共2页 International Eye Science
关键词 角膜磨镶术 激光原位/方法 角膜瓣 游离瓣 钮扣瓣 keratomileusis laser in situ/methods corneal flap free cap buttonhole
  • 相关文献

参考文献5

二级参考文献22

  • 1陈跃国,夏英杰,仲艳莹.M2显微角膜刀制作角膜瓣可预测性分析[J].中国实用眼科杂志,2004,22(7):532-534. 被引量:27
  • 2Solomon KD,Donnenfeld E,Sandoval HP,et al.Flap thickness accuracy:comparison of 6 microkeratome models[J].Cataract Refract Surg,2004,30(5):964-977.
  • 3Seo KY,wan XH,Jang JW,et al.Eeffect of micmkeratome suction duration on corneal flap thickness and micision angle[J].J Refract Surg,2002,18(6):715-719.
  • 4Flanagan GW,Binder PS.Precision of flap measurements for laser in situ keratomileusis in 4428 eyes[J].J Refract Surg,2003,19(2):113-148.
  • 5Genth U,Mrochen M,W(a)lti R,et al.Optical low coherence refrectometry for noncontact measurements of flap thickness during laser in situ keratomileusis[J].Ophthalmology,2002,109(5):973-978.
  • 6Muallem MS,Yoo SY,Romano AC,et al.Corneal flap thickness in laser in situ keratomileusis using the Moria M2 microkeratome[J].J Cataract Refract Surg,2004,30(9):1902-1908.
  • 7Pepose JS,Feigenbaum SK,Qazi MA,et al.Comparative performance of the Zyoptix XP and Hansatome zero-compression microkeratomes[J].J Cataract Refract Surg,2007,33(8):1386-1391.
  • 8Seiler T,Koufala K,Richter G.Iatrogenic keratectasia after laser in situ keratomileusis[J].J Refract Surg,1998,14(3):312-316.
  • 9Choi Y,Parks J,Song BJ.Corneal flap dimensions in laser in situ keratomileusis using the innovatome automatic microkeratome[J].Korean J Ophthalmol,2000,14(1):7-11.
  • 10Sharam N,Pangtey MS.Surgically in duced astigmatism after laser in situ keratomileusis for spherical myopia[J].J Refract Surg,2002,18(3):239-244.

共引文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部