摘要
广州市某冷库一台冷凝器压缩机在试压检漏时发生整体爆炸。经现场调查和对爆炸碎片、残骸的研究,分析了爆炸的过程,判断事故原因为试压工艺问题和操作不当,并给出了改进措施。
A condenser compressor of a Guangzhou based refrigeratory explored entirely when performing pneudraulic testing and leakage checking.The accident site,the debris,the explosion and the conclusion were analyzed.The explosion was caused by the wrong testing procedure and mis-operation of the worker.Also preventive measure was provided to the user.
出处
《流体机械》
CSCD
北大核心
2010年第6期82-84,共3页
Fluid Machinery
关键词
压缩机
爆炸
试压
compressor
explosion
pneudraulic test