摘要 为了建立电力系统运行风险评估中的变压器时变停运模型,给出了基于变压器本体状态监测信息估计内部潜伏性故障的故障率的方法。首先分析了变压器内部潜伏性故障的发展机理,对现有的变压器内绝缘老化模型进行了评述,指出其不适用于估计内部潜伏性故障的故障率。然后选择了能够综合反映内部潜伏性故障发展速率的油中溶解气体分析信息作为表征潜伏性故障发展程度的特征信息,建立估计故障率的多状态马尔可夫过程模型。最后给出了数值算例。 A condition based failure rate estimation method for transformer internal latent fault analysis is proposed. The method is used to develop time-varying transformer outage model for operational risk assessment purpose. Firstly,the operating mechanism in developing process of transformer internal latent fault is analyzed,and some comments are given on the existing aging models of transformer internal insulation. Then,dissolved gas analysis (DGA) outcome is used as an indicator to classify transformer’s operating condition. The multi-state Markov process based mathematical estimation model is proposed to estimate the failure rate. Finally,a numerical test is presented.
出处 《电力系统自动化》 EI CSCD 北大核心 2010年第15期9-13,95,共6页 Automation of Electric Power Systems
基金 国家重点基础研究发展计划(973计划)资助项目(2004CB217908) 国家自然科学基金资助项目(50707013)~~
关键词 运行风险评估 时变停运模型 变压器 绝缘老化 油中溶解气体分析 马尔可夫过程 故障率 operational risk assessment time-varying outage model transformer insulation aging dissolved gas analysis (DGA) Markov process failure rate
  • 相关文献

参考文献13

  • 1CIGRE Task Force 38. 03. 12. Power system security assessment., a position paper. Electra, 1997(175): 49-77.
  • 2吴文传,宁辽逸,张伯明,何云良,冯永青.一种考虑二次设备模型的在线静态运行风险评估方法[J].电力系统自动化,2008,32(7):1-5. 被引量:51
  • 3宁辽逸,吴文传,张伯明.电力系统在线运行风险中架空线路的时变停运模型//周孝信,郭剑波,孙元章.大型互联电网运行可靠性基础研究(II).北京:清华大学出版社,2008:93-103.
  • 4NING Liaoyi, WU Wenchuan, ZHANG Boming. A condition based power system operational risk assessment method// Proceedings of the International Conference on Electrical Engineering, July 5-9, 2009, Shenyang, China.
  • 5宁辽逸,吴文传,张伯明.电力系统运行风险评估中元件时变停运模型分析[J].电力系统自动化,2009,33(16):7-12. 被引量:57
  • 6IEEE Std C57. 91- 1995 IEEE guide for loading mineral oil immersed transformers. 1995.
  • 7GB/T15164-94油浸式电力变压器负载导则.1994.
  • 8MUTHANNA K T, SARKAR A, DAS K, et al. Transformer insulation life assessment. IEEE Trans on Power Delivery, 2006, 21(1):150- 156.
  • 9JARDINI J A, SCHMIDT H P, TAHAN C M V, et al. Distribution transformer loss of life evaluation: a novel approach based on daily load profiles. IEEE Trans on Power Delivery, 2000, 15(1) : 361-366.
  • 10郭永基.中小容量电力变压器寿命评估的新方法[J].电力系统自动化,2001,25(21):38-41. 被引量:39