期刊文献+

多普勒超声波流量的采集与处理研究 被引量:4

Research on Collection and Treatment of Doppler Ultrasonic Flow
在线阅读 下载PDF
导出
摘要 针对多普勒超声波流量计存在测量精度不高的问题,采用离散傅里叶变换方法进行功率谱分析,利用DSP处理数据.分析了多普勒超声波工作原理,研究了离散傅里叶变换进行功率谱分析的算法.根据多普勒超声波工作原理,设计了流量采集和处理电路,分析了电路设计的原理与作用.通过流量计在复杂环境下试验测试,其引用误差均小于1%,明显提高了流量计的测量精度. The analysis of power spectrum by using discrete fourier transform is made and the process of data by using DSP is proposed to solve the problem of low accuracy of dopplor ultrasonic flow meters.The working principle of the Doppler ultrasound is introduced and the algorithm for power spectrum analysis by using discrete Fourier transform is studied;Based on the principle of Doppler ultrasound,flow meter collection and processing circuits are designed.The design principle and the role of the circuit are analyzed.When the flow meter is tested in a complex environment,its reference error is less than 1%.The experimental results show that the measurement accuracy of the flowmeter is improved greatly.
出处 《西安工业大学学报》 CAS 2010年第5期487-490,510,共5页 Journal of Xi’an Technological University
基金 兵器工业总公司"十一.五"预研项目
关键词 频谱分析 超声多普勒 数据处理 流量测量 spectrum analysis ultrasonic Doppler data processing flow measurement
  • 相关文献

参考文献7

二级参考文献22

  • 1张树春,刘成安.基于USB总线的FPGA与PC机接口通信的实现[J].微计算机信息,2005,21(4):202-203. 被引量:9
  • 2阎石.数字电子技术基础 [M].北京:高等教育出版社,1994..
  • 3应启 赵学端.流量检测及仪表 [M].上海:上海交通大学出版社,1987..
  • 4吕汉兴,盛翊智.多声道超声多普勒流量计[J].工业仪表与自动化装置,1997(3):24-27. 被引量:10
  • 5[3]严钟豪,谭祖根. 非电量电测技术[M]. 机械工业出版社, 1994.
  • 6Complete DDS Synthesizer AD9850 Data Sheet,Analog Device Inc.,1998.
  • 7RS232 Transceivers MK202E Data Sheet.MAXIM.1999.
  • 8High - Speed Analog - To - Digital Converter ADS803 Data Sheet, Burr - Brown, 1997Corporation.
  • 9TMS320C20/C2XX/C5X C Source Debugger User's Guide, Texas Instruments, 1995.
  • 10TMS320F206 Digital Signal Processor Data Sheet, Texas Instruments, 1996.

共引文献34