摘要 Flat plate pulsating heat pipe is useful for hot spot heat spreader. Two kinds of flat plate spreader of pulsating heat pipe are designed, fabricated and experimented. For the embedded circular capillary type, the transferred heat flux could reach 32 W/cm2, the smallest thermal resistance for acetone, methanol and FC-72 were respectively 0.50, 0.57 and 0.40℃/W. While for the square capillary type, the transferred heat flux could reach 26 W/cm2, the equivalent thermal conductivity could reach 3211 W/(m. ℃). There are ranges of optimal transferred power and filling ratio for different working liquid. If the transferred power is constant, changing the heating area and the place has little effects on the performance.
作者 W. Qu B. Yang
出处 《Journal of Energy and Power Engineering》 2010年第8期1-8,共8页 能源与动力工程(美国大卫英文)
关键词 Pulsating heat pipe heat spreader the embedded circular capillary type the square capillary type heat flux. 脉动热管 性能影响 平板式 等效导热系数 热管散热器 供热面积 热通量 嵌入式
  • 相关文献

参考文献11

  • 1R.C. Chu, R.E. Simons, G.M. Chrysler, Experimental investigation of an enhanced thermosyphon heat loop for cooling of a high performance electronics module, in: Proc. of 15th IEEE Semi-Thermo Symposium, San Diego, Canada, 1999.
  • 2P. Meena, S. Rittidech, N. Poomsa-ad, Application of closed-loop oscillating heat-pipe with check valves (CLOHP/CV) air-preheater for reduced relative-humidity in drying systems, Applied Energy 84 (2007) 553-556.
  • 3Z. Zuo, M. North, Miniature high heat flux heat pipes for cooling of electronics, in: Proc. of SEE2000, pp. 573-579.
  • 4T. Wong, P. Terdtoon, P. Sakulchangsatjatai, Operation moldeling of closed-end and closed-loop oscillating heat pipes at normal operating condition, Applied Thermal Engineering 24 (7) (2004) 995-1008.
  • 5W. Qu, T.Z. Ma, Experimental Investigation on Flow and Heat Transfer of a Pulsating Heat Pipe. Proceedings of 12th Int. Heat Pipe Conference, Moscow, Russia, 2002, 226-231.
  • 6S. Khandekar, P. Charoensawan, M. Groll, P. Terdtoon, Closed loop pulsating heat pipes Part B: visualization and semi-empirical modeling, Applied Thermal Engineering 23 (2003) 2021-2033.
  • 7P. Charoensawan, Nondimensional correlation to predict the thermal performance of horizontal closed-loop pulsating heat pipe, in: 14th Int. Heat Pipe Conference, Florianopolis, Brazil, Apr. 22-27, 2007.
  • 8P. Charoensawan, S. Khandekar, M. Groll, Closed looped pulsating heat pipes: Part A: parametric experimental investigation, Applied Thermal Engineering 23 (2003) 2009-2020.
  • 9A. Bensalem, C. Romestant, A. Alexandre, Y. Bertin, Experimental investigation of pulsating heat pipes, in: 14th Int. Heat Pipe Conference, Florianopolis, Brazil, Apr. 22-27. 2007.
  • 10S. Khandekar, N. Dollinger, M. Groll, Understanding operational regimes of closed loop pulsating heat pipes: an experimental study, Applied Thermal Engineering 23 (2003) 707-719.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部