期刊文献+

超声引导改良婴幼儿颈内静脉穿刺置管术的临床研究 被引量:11

Clinical Application Study of Ultrasound-Guided Internal Jugular Vein Catheterization in Infants
在线阅读 下载PDF
导出
摘要 目的:探讨超声引导改良婴幼儿颈内静脉穿刺置管术的临床应用价值。材料和方法:随机抽取行先天性心脏病手术的婴幼儿60例分为2组(n=30)。A组:对照组,首选右颈内静脉中路,用20GY形穿刺针穿刺,再经Y型穿刺针置入J形引导钢丝,然后置入中心静脉导管。B组:实验组,在超声引导下用18GBD静脉外套管穿刺,经静脉外套管置入J形引导钢丝,然后置入中心静脉导管。记录两组穿刺置管总成功率、一次穿刺成功率、失败率及并发症。结果:B组总穿刺成功率高于A组(P<0.05),B组一次穿刺成功率显著高于A组(P<0.01),B组的穿刺并发症明显低于A组。结论:超声引导下经18G静脉留置针穿刺置管,大大提高了婴幼儿中心静脉置管的成功率,并降低了并发症的发生率,有很高的临床应用价值。 Purpose To evaluate the clinical value of ultrasound-guided internal jugular vein (IJV)catheterization in infant patients. Materials and Methods Sixty infant patients aged between 30 days and 3 years with weight ranging from 3.70 to 15.0 kg who underwent surgery due to congenital heart diseases were recruited in this study. The patients were divided into two groups according to the catheterization approach: control group (catheterization by midway approach, n = 30)and experimental group (catheterization guided by ultrasonography, n=30). The overall success rate of catheterization, the success rate of catheterization at first attempt, and the complications during catheterization in two groups were recorded and compared. Results The overall success rate of catheterization and the success rate of catheterization at first attempt in experimental group were significantly higher than those in the control group (100%vs. 80%, P〈0.05; 93.3%vs. 70%,P〈0.01), respectively. In addition, the complication rate in experimental group was lower than that in the control group (0%vs. 26.7%). Conclusions Internal jugular vein catheterization guided by ultrasound is a reliable and safe technique in infant patients.
作者 刘树文
出处 《中国医学影像学杂志》 CSCD 北大核心 2011年第1期62-65,共4页 Chinese Journal of Medical Imaging
关键词 超声检查 儿童 颈内静脉 静脉穿刺术 ultrasonography child carotid vein, internal vein puncture
  • 相关文献

参考文献10

二级参考文献37

  • 1徐树彬,郭斌,张冉.心脏直视手术患者颈内静脉穿刺致血管损伤性出血四例[J].中华麻醉学杂志,2004,24(10):799-800. 被引量:5
  • 2袁建毛,高泉根,邱建平,谢峰.高位前内侧途径经右颈内静脉建立中心静脉通道[J].现代医学,2005,33(4):270-273. 被引量:1
  • 3Riopelle JM, Ruiz DP, Hunt JP, et al. Circunfferential adjustment of ultrasound probe position to determine the optimal approach to the internal jugular vein: a noninvasive geometric study in aduhs. Anesth Analg,2005,100:512-519
  • 4Lichtenstein D, Saifi R, Augarde R, et al. The Internal jugular veins are asymmetric. Usefulness of ultrasound before catheterization. Intensive Care Med, 2001,27:301-305.
  • 5Gordon AC, Saliken JC, Johns D, et al. US-guided puncture of the internal jugular vein: complications and anatomic considerations.J Vasc Interv Radiol, 1998,9 : 333-338.
  • 6[1]Armstrong PJ, Cullen M, Scott DHT. The"Site Rite"ultrasound machine-an aid to internal jugular vein cannulation. Anaesthesis. 1993,48:319-323.
  • 7[3]Mark SS, David BK, David LL. An anteromedial internal jugular vein successfully cannulated using the assistance of ultrasonography. Journal of Clinical Anesthesia, 2000, 12: 83-86
  • 8[4]Denys BG, Uretsky BF. Anatomical variations If internal jugular vein location: impact on central venous access. Critical Care Medicine. 1991, 19:1516-1519
  • 9Nicolson SC, Sweeney MF, Moore RA, et al. Comparison of internal and external jugular cannulation of the central circulation in the pediatric patient. Crit Care Med, 1985,13(9):747-749.
  • 10Verghese ST, McGill WA, Patel RI, et al. Ultrasound-guided internal jugular venous cannulation in infants: a prospective comparison with the traditional palpation method. Anesthesiology,1999,91(1):71-77.

共引文献94

同被引文献63

引证文献11

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部