定子绕组诊断的分离电压和电流正负序分量法 被引量:2

Fault Diagnosis of Induction Motor's Stator Winding by Positive and Negative Sequence Component of Voltage and Current Separation Method
在线阅读 下载PDF
导出
摘要 感应电机早期定子绕组故障表现不明显,并且受到电源和负载等外部条件的影响而难以准确检测,如瞬时功率分解法受转子转速、电流波动和电源频率影响较大;对称分量法处理定子绕组不对称问题的效果不理想;同步速坐标变换法计算复杂。为此引入了分离定子电压和电流正负序分量的方法来提取故障特征。采集到的数据先进行低通滤波处理,减弱高次谐波和噪声的影响。采用电源变换消除对负序分量来源的判断;Park变换将信号从三维坐标转换到二维坐标中;Hilbert变换的频率相移特性可以分离信号的正负序分量。仿真结果表明:该方法可以消除其他非故障因素的影响,准确提取定子电压和电流的正负序分量,并可根据电源的不对称度,分别采用定子负序电流和负序阻抗来表征故障的严重程度。该方法解决了早期定子绕组故障检测的难题,可应用于实际工程中。 Early faults of induction motors' stator winding feature is not distinct,and it is liable to the influence of power,load and other outer factors,so the accurate measurement of which is difficult.A method of positive and negative sequence component based on separation of stator voltage and current was introduced to extract the features of fault.First,the acquired data was filtered by low-pass filter to weaken the influence of high-harmonics and yawp.Power transformation could eliminate source judgment of negative component.Park transformation converted the signal from 3-D coordinate axis to 2-D coordinate axis.Hilbert transformation had frequency phase-change quality to separate positive and negative components.Simulation results showed that this method could avoid none-fault factors' effect and obtain positive and negative components of stator voltage and current.Finally,it adopted stator negative current and negative impedance to describe fault severity degree.This method solveed the problems on stator early fault examine.
出处 《探测与控制学报》 CSCD 北大核心 2011年第1期23-26,31,共5页 Journal of Detection & Control
基金 空军科研基金资助(KJZ06623)
关键词 故障诊断 感应电机 定子绕组 fault diagnosis induction motor stator winding
  • 相关文献

参考文献7

二级参考文献64

共引文献85

同被引文献7

引证文献2

二级引证文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部