Easyshape根管预备系统的概述
被引量:2
Outline of Easyshape root canal preparatory system
摘要
Easyshape根管预备器械是新型的机动镍钛预备系统,相比其他的机动镍钛系统,它有自己的设计特点和使用方法,它采用的是全长预备,有着双"s"形的横截面,能有有效的进行切割。本文对这种镍钛器械进行系统的介绍。
出处
《口腔材料器械杂志》
2011年第2期99-100,109,共3页
Chinese Journal of Dental Materials and Devices
参考文献19
-
1Luiten DJ, Morgan LA, Baumgartner JC, et al. A comparison of four instrumentation techniques on apical canal transportation. [ J ] J Endod, 1995,21 ( 1 ) :26 - 32.
-
2Yun HH, Kim SK. A comparision of the shaping abilities of 4 nick- el-- titanium rotary instruments in simulated root canals. Oral StagO- ral Med Oral Pathol Oral Radiol Ended. 2003,95:228 - 233.
-
3Krupp JD, Brantley WA, Gerstein H. An investigation of thetorsion- al and bending properties of seven brands of endodonfic fdes. J0f En- ded , 1984,9:372 - 380.
-
4Berutti E, Cantatore G, Castellucci A, et al. Use of nickel-titanium ro- tary PathFile to create the glide path: comparison with manual preflaring in simulated root canals. J Ended. 2009 Mar;35(3):408 -12.
-
5Plotino G, Grande NM, Sorci E, et al. Influence of a brushing work- ing motion on the fatigue life of NiTi rotary instruments. [ J ] Int Endod J,2007,40( 1 ) : 45 - 51.
-
6Kum KY, Spangberg L, Cha BY, et al. Shaping ability profile rotary instrumentation in simulated resin root canal. [ J] J Endod,2000,26 (12) :719 -723.
-
7Burklein S, Schafer E. The influence of various automated devices on the shaping ability of Mtwo rotary nickel-titanium instruments. [J].Int Endod J,2006. (39) : 945 -951.
-
8葛久禹.根管治疗学.第二版,江苏科技出版社[M],2007:114.
-
9Kum KY, Spangberg L, Cha BY, et al. Shaping ability profile rotary instrumentation in simulated resin root canal. [ J] J Endod,2000,26 (12) :719 -723.
-
10Tasdemir T, Er K, Yildirim T, et al. Efficacy of three rotary NiTi in- struments in removing gutta-percha from root canals. [ J ] Int Endod J, 2008, 41 (3) :191 -6.
二级参考文献22
-
1郭继华,彭彬,范兵,边专.镍钛合金器械预备弯曲根管的临床评价[J].中华口腔医学杂志,2001,36(6). 被引量:21
-
2史俊南 赵皿 蔡绍惠.1400个恒牙根尖解剖的初步研究.中华口腔科杂志,1964,10(5):320-320.
-
3Smith CS, S techell DI, Harry FJ. Factors influencing the success of conventional root canal therapy - a 5 - year retrospective study. Int Endo J, 1993,26:321 - 333.
-
4Yun HH, Kim SK. A comparision of the shaping abilities of 4 nickel -titanium rotary instruments in simulated root canals. Oral Surg Oral Med Oral Pathol Oral Radiol Ended ,2003,95:228 -233.
-
5Krupp JD, Brantley WA, Gerstein H. An investigation of the torsional and bending properties of seven brands of endodontie f'des. Jof Endod, 1984, 9:372 - 380.
-
6Schneider SW. A comparision of canal preparation in straight and curved root canals. Oral Surg Oral Med Oral Pathol ,1971,32:271 - 275.
-
7About- Rass M, Jastrab RJ. The use of rotary instruments as auxiliary aids to root canal preparation of molars. J of Endod, 1982, 8:78-82.
-
8Luiten D J, Morgan LA, Baugartner JC, et al. A eomparision of four instrumentation techniques on apical canal transportation. J of Endod, 1995, 21:26 -32.
-
9Buchanan IS. The standardized taper root canal preparation:part 1. concepts for variably tapered shaping instruments. Int Endod J, 2000, 33:516-529.
-
10Yared GM. Behavior of Hero NITI instruments used by an experienced operator under access limitations. Aust Endod J, 2002, (2):64.
共引文献35
-
1刘沛,凌均棨,高燕.机用镍钛器械预备清理根管效果的定量分析[J].牙体牙髓牙周病学杂志,2004,14(3):158-161. 被引量:12
-
2夏智敏,彭彬,边专,樊明文.两种侧方加压器进入弯曲根管深度的实验研究[J].牙体牙髓牙周病学杂志,2004,14(10):567-570. 被引量:4
-
3张丽,张彤.不同根管器械用于预备弯曲根管的效果比较[J].中国基层医药,2005,12(1):31-32. 被引量:1
-
4万阔,李玉彬,景权,刘翠凤.使用微焦点CT对四种根管预备器械根管预备效果的研究[J].北京口腔医学,2005,13(2):111-114. 被引量:6
-
5郅洁云.二种机用镍钛锉预备老年患者磨牙弯曲根管疗效观察[J].中华老年口腔医学杂志,2010,8(6):332-334. 被引量:2
-
6于俊光,刘祺,李牟.机动镍钛锉根管预备行根充术的临床疗效分析[J].黑龙江医药科学,2005,28(5):87-87.
-
7戴丽霞,张良付,周中苏.镍钛机动器械预备在根管治疗一次法中近期疗效[J].现代口腔医学杂志,2005,19(6):661-661.
-
8王朝红,申莲英.292例根管充填质量的临床评价[J].社区医学杂志,2006,4(05S):15-16.
-
9缪键,王聪.两种机用镍钛器械预备根管的疗效评价[J].四川医学,2008,29(6):733-735. 被引量:1
-
10刘士颖.机用镍钛器械预备弯曲根管临床应用评价[J].实用医院临床杂志,2010,7(1):122-124. 被引量:3
同被引文献21
-
1魏振辉,杜原宏,张鹏,徐莉,徐阳,王金泉,王晓宇,展俊岩.MTWO镍钛根管预备系统在磨牙根管治疗中的应用分析[J].中国实用口腔科杂志,2009,2(5):289-290. 被引量:8
-
2Schneider SW.A comparison of canal preparation in straight and curved mot canals[J].Oral Surg,1971,32:271-275.
-
3Pruett JP,Clement DJ,Carries DL.Cyclic fatigue testing of nickel-titanium endodontic instruments[J].J Endod,1997,23:77-85.
-
4Cunningham CJ,Senia ES_ A three-dimensional study of canal curvatures in the mesial mots of mandibular molars[J].J Endod,1992,18:294-300.
-
5Dobb NC,Jānos S,J d zsef S.A mathematically based classification of mot canal curvatures on natural human teeth[J].J Endod,1995,21:557-560.
-
6Schafer E,Dize C,Hoppe W,et al.Roentgenographic investigation of frequency and degree of canal curvatures in human permanent teeth[J].J Endod,2002,28:211-216.
-
7Roland DD,Andelin WE,Browning DF,et al.The effect of preflaring on the rates of separation for 0.04 taper nickel titanium rotary instruments[J].J Endod,2002,28:543-545.
-
8Hata G,Uemura M,Kato AS,et al.A comparison of shaping ability using Profile,GT file,and Flex-R endodontic instruments in simulated canals[J].J Endod,2002,28:316-231.
-
9Contreras MA,Zinman EH,Kaplan SK.Comparison of the first file that fits at the apex,before and after early flaring[J].J Endod,2001,27:113-116.
-
10Marques J, Eduardo CP, Matsumotok. A study on morphological changes of the root canal walls lased by pulsed ND;YAG laser[J]. J Jpn EndodAsso, 1995, 16(1): 64-71.
二级引证文献16
-
1高洁,吕锦.乙二胺四乙酸凝胶在弯曲根管预备中的应用效果评价[J].实用医院临床杂志,2012,9(4):109-111. 被引量:2
-
2黎新雁,郑书梅,范微微.机用Pathfile^(TM)联合手用ProTaper镍钛器械预备磨牙狭窄根管125例效果评价[J].中国实用口腔科杂志,2015,8(4):242-243. 被引量:2
-
3吴幸晨,王晓洁,朱亚琴.三种运动方式对TF单根镍钛器械在磨牙弯曲根管预备能力的比较研究[J].牙体牙髓牙周病学杂志,2015,25(8):477-482. 被引量:12
-
4于春青,康雪梅,王建国.两种镍钛器械联合预备弯曲根管的效果评价[J].临床口腔医学杂志,2016,32(8):485-487. 被引量:2
-
5陆长玺,朱亚琴.机用MTWO镍钛器械折断的临床观察及影响因素分析[J].口腔材料器械杂志,2016,25(4):189-192. 被引量:3
-
6满都拉.机用镍钛器械预备后牙弯曲根管产生根管偏移的情况[J].全科口腔医学电子杂志,2016,3(4):99-99. 被引量:2
-
7钱才梅,李泽汉,闫明.M3机用镍钛器械预备中度弯曲根管的临床分析[J].南京医科大学学报(自然科学版),2017,37(12):1678-1680. 被引量:11
-
8侯惠敏,魏伦全,韩宇,宋立平,成鹏飞.三种镍钛锉对弯曲根管成形效果的评价[J].中华老年口腔医学杂志,2018,16(3):137-141. 被引量:14
-
9成鹏飞,魏伦全,韩宇,伊丽娜,侯惠敏.两种往复运动镍钛锉根管中心定位能力的研究[J].临床口腔医学杂志,2018,34(7):434-437. 被引量:4
-
10侯惠敏,伊丽娜,韩宇,魏伦全,成鹏飞.三种往复运动镍钛锉根管预备效果的比较[J].北京口腔医学,2018,26(4):205-209. 被引量:6
-
1李林光,朱亚琴.Easyshape和Mtwo两种镍钛预备系统对后牙弯曲根管预备效果的比较[J].口腔材料器械杂志,2013,22(4):189-192. 被引量:2
-
2裘松波,汪志德,林景春.成人前牙反修复治疗的桩核设计特点[J].第三军医大学学报,2001,23(7):764-764.
-
3张卫军.根管预备中根管锉的研究进展(综述)[J].中国城乡企业卫生,2010,25(5):38-38.
-
4赵弘,刘洪臣,顾晓明.微型种植钉在口腔正畸学中的应用[J].口腔颌面修复学杂志,2009,10(4):250-253. 被引量:8
-
5宋亚玲,边专,范兵.非ISO机用镍钛器械成形根管的研究进展[J].国外医学(口腔医学分册),2002,29(1):14-16. 被引量:7
-
6杨小东,刘果生,李兵,吴大怡.CDIC柱状螺纹种植体系统──设计特点与性能[J].中国口腔种植学杂志,1998,3(3):101-106. 被引量:29
-
7梁海,刘进,郭鑫.正畸治疗中磨牙的拔除和保留(二十九)——拔除第一磨牙的矫治设计[J].临床口腔医学杂志,2008,24(4):253-255. 被引量:5
-
8郭惠杰,梁宇红,王嘉德.两种机用镍钛器械根管预备的临床应用研究[J].现代口腔医学杂志,2009,23(3):235-238. 被引量:13
-
9荀文兴,邹敬才,郭庆科,肖光裕,张红梅,杜娟.原长法联合前唇唇红“M”瓣整复双侧唇裂畸形[J].中国美容医学,2003,12(1):78-80. 被引量:2
-
10张彬,李冬梅,冯宝华,李金源.下颌切牙整体压低移动对牙周组织应力变化的三维有限元分析[J].中国煤炭工业医学杂志,2014,17(2):240-242.