Transformer insulation diagnosis based on Multi-peak return voltage curve
在线阅读 下载PDF
导出
摘要 基于介质响应理论的回复电压方法能有效评估单一峰值极化谱的变压器固体绝缘的水分含量,而对于含有多峰值点的极化谱,很难准确评估其固体绝缘状态.针对影响回复电压极化谱的各种因素进行分析,提出判据和评估非标准极化谱的方法,提高了利用极化谱判断固体绝缘状况的可靠性和准确性。该方法在工程实际应用中具有参考价值. Return voltage measurement(RVM) is an effective dielectric response test method,which has been used to evaluate moisture level of solid insulation.In the process of field test,the obtained polarization spectrum is non-standard which is affected by many factors,and the insulation status of dielectric is hard to judge.Factors that impact field test return voltage polarization spectrum are analyzed,and methods of judging and explaining the non-standard polarization spectrum are presented in this paper.The reliability and preciseness of judging solid insulation status with polarization spectrum are improved.The proposed methods have great reference value in engineering application.
出处 《电力科学与技术学报》 CAS 2011年第3期46-51,共6页 Journal of Electric Power Science And Technology
基金 福建省自然科学基金(2010J01283)
关键词 变压器 回复电压 非标准极化谱 残余电荷 transformer return voltage non-standard polarization spectrum residual charge
  • 相关文献

参考文献15

二级参考文献83

  • 1宋伟,A.J.Kachler.变压器老化评估的极化去极化电流分析法[J].变压器,2005,42(7):28-34. 被引量:25
  • 2杨丽君,廖瑞金,孙才新,李剑,梁帅伟.油纸绝缘老化阶段的多元统计分析[J].中国电机工程学报,2005,25(18):151-156. 被引量:34
  • 3KALOCSAL L.Spectrum of Polarization Phenomena of Long Time-constant as a Diagnostic Method of Oil-paper Insulation System[C].Proceeding of the 3rd International Conference on Properties and Application of Dielectric Materials.Tokyo, Japan:IEEE Dielectrics and Electrical Insulation Society and Insitute of Electrical Engineens of Japan, 1991:723-726.
  • 4NEMETH E.Measuring Voltage Response: a Non-destructive Diagnostic Test Method of HV Insulation[J].IEE Proceeding of Science.Measurement and Technology, 1999,146(5) :249-252.
  • 5Tokyo Electric Co. Inc Hitachi,Ltd.A Diagnostic Method Based on RVM (Return Voltage Measurement)for Condenser Bushing with Oil-Paper Insulation Systems[J].Electric Engineering in Japan, 2000,130( 1 ) : 21-29.
  • 6ASCHENBRENNER V.Using of Parameters of RVM Measurement for Qualitative Appreciation of Power Transformers Insulation States[C].Transmission and Distribution Conference and Exhibition.2002,1 829-1 833.
  • 7OMAR HASSANL,HOSSEIN BORSIL,EMST GOCKENBACH, et al.Diagnostic of Insulation Condition of oil Impregnated Paper Insulation System with Return Voltage Measurements[C].2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.USA : IEEE Dielectrics and Electrical Insulation Society,2003 : 153-156.
  • 8E. NEMETH. Measuring the Voltage Response,A Diagnostic Test Method of Insulations[C].Seventh International Symposium on High Voltage Engineering.Dresden, Germany:Dresden University of Technology, 1991 : 63-66.
  • 9TAPAN KUMAR SAHA,ZHENG Tong Yao.Experience With Return Voltage Measurements for Assessing Insulation Conditions in Service-Aged Transformers[J].IEEE Transactions on Power Delivery ,2003,18( 1 ) : 128-135.
  • 10OMAR HASSANL,HOSSEIN BORSIL,EMST GOCKENBACH. Diagnostic of Insulation Condition of Oil Impregnated Paper Insulation System with Return Voltage Measurements[C].2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena,Albuquerque,New Mexico,USA :IEEE Dielectrics and Electrical Insulation Society,2003:153-156.

共引文献177

同被引文献26

  • 1宋伟,A.J.Kachler.变压器老化评估的极化去极化电流分析法[J].变压器,2005,42(7):28-34. 被引量:25
  • 2董明,张瑞刚,张冠军,严璋.回复电压法在变压器故障诊断中的应用[J].电网与水力发电进展,2007,23(3):21-25. 被引量:18
  • 3Islam S M,Jota P R S,Stace M. Detection of oil-paper e- quilibrium moisture content in power transformers u- sing hybrid intelligent interpretation of polarisation spectrums from recovery voltage measurements [ C]. IEEE International Symposium on Electrical Insulation, Arlington, USA, 1998.
  • 4Blennow J, Ekanayake C, Walczak K, et al. Field experi- ences with measurements of dielectric response in fre- quency domain for power transformer diagnostics [J]. IEEE Transactions on Power Delivery, 2006, 21 (2): 681-688.
  • 5Ekanayake C,Gubanski S M, Graczkowski A, et al. Fre- quency response of oil impregnated pressboard and pa- per samples for estimating moisture in transformer in- sulation[J]. IEEE Transactions on Power Delivery, 2006,21(3) .1 309-1 317.
  • 6Saha T K, Purkait P. Understanding the impacts of moisture and thermal ageing on transformer's insula- tion by dielectric response and molecular weight meas- urements[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2008,15 (2) : 568-582.
  • 7Li M H,Dong M,Qu Y M,et al. Return voltage meas urements of oil impregnated paper insulated transform ers[C]. IEEE International Symposium on Electrical In sulating Materials, Japan, 2005.
  • 8LI M H, DONG M, QU Y M, et al. Return voltage measurements of oil impregnated paper insulated transformers [ C] //Proceedings of 2005 International Symposium on Electrical Insulating Materi- als, 205, June 5-9, 2005, Kitakyushu, Japan. 2005, 1:273 - 276.
  • 9VAN B J P, GULSKI E, SMIT J J, et al. Development of knowl- edge rules for RVM for interpretation of the condition of transformer insulation [ C ]//Conference Record of the 2000 IEEE International Symposium on Electrical Insulation, Apr 2 - 5, 2000, Anaheim, USA. 2000 : 267 - 270.
  • 10BOGNAR. A, CSEPES G, KALOCSAI L, et al. Spectrum of po- larization phenomena of long time - constant as a diagnostic method of oil - paper insulating system [ C ]//Proceedings of the 3 rd Inter- national Conference on Properties and Applications of Dielectric Materials, July 8-12, 1991, Tokyo, Japan. 1991,2:723-726.

引证文献3

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部