期刊文献+

心律失常患者冠状动脉CTA成像 被引量:2

Coronary computed tomography angiography in patients with arrhythmia
在线阅读 下载PDF
导出
摘要 冠状动脉CT血管造影(CTA)目前已广泛应用于临床,但心律失常患者一直是此项技术的瓶颈。由于传统的螺旋CT及双源CT的技术限制,对心律失常患者扫描过程中往往因为心脏运动不规律,导致图像不连续。心电编辑技术可解决部分此类问题,改善图像的质量,提高诊断的灵敏度。宽探测器CT(如320排螺旋CT)在低心率条件下可在一个心动周期成像,能消除此类伪影,但时间分辨力尚待提高。 Coronary computed tomography angiography(CTA) has been widely applied in clinical practice,but arrhythmia has always been the bottleneck of the technology.Limited by the technological problems of multidetector spiral CT and dual-source CT,images always discontinue for the irregular cardiac rhythm.Electrocardiograph editing technology can improve image quality and diagnostic sensitivity.Wide-detector CT can rebuild the images by a single heartbeat in the case of low heart rate,which helps to eliminate artifacts,but its temporal resolution needs to be improved.
作者 何雯雯 黄伟
出处 《心脏杂志》 CAS 2012年第1期123-126,共4页 Chinese Heart Journal
关键词 心律失常 冠状动脉 计算机体层摄影 血管成像 心电描记术 arrhythmia coronary artery tomography angiography electrodiography
  • 相关文献

参考文献19

  • 1Lloyd-Jones D,Adams RJ,Brown TM,et al.Heart disease andstroke statistics--2010 update:a report from the American Heart As-sociation[J].Circulation,2010,121(7):e46-e215.
  • 2齐燕,齐双,欧陕兴.双源CT在心脏成像中的应用研究[J].心脏杂志,2010,22(2):302-304. 被引量:5
  • 3Meijboom WB,Meijs MF,Schuijf JD,et al.Diagnostic accuracy of64-slice computed tomography coronary angiography:a prospective,multicenter,multivendor study[J].J Am Coll Cardiol,2008,52(25):2135-2144.
  • 4Johnson TR,Nikolaou K,Busch S,et al.Diagnostic accuracy ofdual-source computed tomography in the diagnosis of coronary arterydisease[J].Invest Radiol,2007,42(10):684-691.
  • 5Weustink AC,Neefjes LA,Kyrzopoulos S,et al.Impact of heartrate frequency and variability on radiation exposure,image quality,and diagnostic performance in dual-source spiral CT coronary angi-ography[J].Radiology,2009,253(3):672-680.
  • 6Matsutani H,Sano T,Kondo T,et al.ECG-edit function in mul-tidetector-row computed tomography coronary arteriography for pa-tients with arrhythmias[J].Circ J,2008,72(7):1071-1078.
  • 7覃杰,刘凌云,孟晓春,朱康顺,何可可,钱孝贤,赵长林,单鸿.320排动态容积CT冠状动脉成像的临床应用[J].中国医学影像技术,2009,25(9):1598-1600. 被引量:38
  • 8Rybicki FJ,Otero HJ,Steigner ML,et al.Initial evaluation of coro-nary images from 320-detector row computed tomography[J].Int JCardiovasc Imaging,2008,24(5):535-546.
  • 9姚静,许迪,陆凤翔,雍永宏,季玲,曹克将.速度向量成像对右室起源室性期前收缩左心室收缩期旋转运动的研究[J].中华超声影像学杂志,2008,17(6):479-483. 被引量:8
  • 10姚静,许迪,陆凤翔,雍永宏,庄燕,季玲,曹克将.右心室流出道起源室性期前收缩患者左心室收缩同步性及时序的研究[J].中华超声影像学杂志,2010,19(6):461-464. 被引量:6

二级参考文献108