期刊文献+

CT三维重建与颈椎弓根测量 被引量:3

CT three-dimensional reconstruction and cervical pedicle measurement
在线阅读 下载PDF
导出
摘要 背景:三维重建技术能够提供人体内部结构的数字化三维模型,并利用相关软件在模型上进行手术设计和生物力学分析,为椎弓根螺钉的安全有效置入提供可靠数据。目的:综述CT三维重建在颈椎弓根测量中的应用。方法:应用计算机检索1990/2011PubMed数据库、维普数据库及万方数据库中有关CT三维重建在颈椎弓根测量中应用的文献,英文检索词为"thre edimensional reformation sofmulti-slicespiral CT;cervical pedicle";中文检索词为"颈椎弓根;三维CT;计算机辅助设计;脊柱外科;数字骨科;医学图像"。结果与结论:应用CT三维重建技术可以获得清晰颈椎三维图像。颈椎椎弓根螺钉置入技术因颈椎椎弓根变异较大,临近解剖结构复杂,目前国内仅少数医院得以成功开展。而利用三维CT重建测量颈椎弓根可以模拟椎弓根螺钉置入技术,能够真实准确地观察和测量椎弓根螺钉在椎体内的情况,获取个体化解剖数据,为临床应用椎弓根螺钉置入技术提供指导。 BACKGROUND:Three-dimensional reconstruction technique can provide digital three-dimensional model of human internal structure.Surgery design and biomechanical analysis were conducted on the model using relevant software,which can provide reliable data for safe effective implantation of pedicle screw.OBJECTIVE:To review the application of CT three-dimensional reconstruction in cervical pedicle measurement.METHODS:We retrieved PubMed Database,Vip Database and Wanfang Database for literature regarding the application of CT three-dimensional reconstruction in cervical pedicle measurement published from 1990 to 2011.The English were "three dimensional reformations of multi-slice spiral CT,cervical pedicle".The Chinese key words were "cervical pedicle,three-dimensional CT,computer-aided design,spinal surgery,digital orthopedics,medical image". RESULTS AND CONCLUSION:Using CT three-dimensional reconstruction technique could obtain clear three-dimensional image of cervical vertebra.Due to the great variation of cervical pedicle and complicated anatomic structure,cervical pedicle screw implantation has been used in a few hospitals in China.However,three-dimensional CT reconstruction for measuring cervical pedicle simulated pedicle screw implantation,exactly observed and measured pedicle screw conditions in vivo,and obtained individual anatomic data,which provided guidance for clinical application of pedicle screw implantation.
出处 《中国组织工程研究》 CAS CSCD 2012年第13期2415-2418,共4页 Chinese Journal of Tissue Engineering Research
基金 新疆塔城地区科学研究(公关)基金项目~~
  • 相关文献

参考文献21

  • 1数字骨科学:三维重建技术与椎弓根螺钉置入[J].中国组织工程研究与临床康复,2010,14(35):6581-6582. 被引量:1
  • 2朱若夫,杨惠林,李继刚,胡春洪,王根林,唐天驷.多层螺旋CT三维重建国人下颈椎椎弓根的临床解剖学意义[J].中国组织工程研究与临床康复,2011,15(30):5582-5586. 被引量:7
  • 3Bozbuga M,Ozturk A,Ari Z. Morphometric evaluation of subaxial cervical vertebrae for surgical application of transpedicular screw fixation[J].Spine (Phila Pa 1976),2004,(17):1876-1880.
  • 4Kothe R,Ruther W,Schneider E. Biomechanical analysis of transpedicular screw fixation in the subaxial cervical spine[J].Spine (Phila Pa 1976),2004,(17):1869-1875.
  • 5Sakamoto T,Neo M,Nakamura T. Transpedicular screw placement evaluated by axial computed tomography of the cervical pedicle[J].Spine (Phila Pa 1976),2004,(22):2510-2514.
  • 6Kayalioglu G,Erturk M,Varol T. Morphometry of the cervical vertebral pedicles as a guide for transpedicular screw fixation[J].Neurologia Medico-Chirurgica(Tokyo),2007,(07):102-107.
  • 7Panjabi MM,Shin EK,Chen NC. Internal morphology of human cervical pedicles[J].Spine (Phila Pa 1976),2000,(10):1197-1205.
  • 8Shin EK,Panjabi MM,Chen NC. The anatomic variability of human cervical pedicles:considerations for transpedicular screw fixation in the middle and lower cervical spine[J].European Spine Journal,2000,(01):61-66.
  • 9Vara CS,Thompson GH. A cadaveric examination of pediatric cervical pedicle morphology[J].Spine (Phila Pa 1976),2006,(10):1107-1112.
  • 10Yusof MI,Ming LK,Abdullah MS. Computerized tomographic measurement of the cervical pedicles diameter in a Malaysian population and the feasibility for transpedicular fixation[J].Spine (Phila Pa 1976),2006.221-224.

二级参考文献102

共引文献81

同被引文献47

  • 1陈立言,彭新生,李佛保,廖威明,万勇.椎弓根钉固定在10岁以下小儿胸腰椎疾患治疗中的应用[J].中国脊柱脊髓杂志,2006,16(4):263-266. 被引量:13
  • 2谭明生,张光铂.浅谈寰枢椎脱位的治疗选择与手术适应证[J].中国脊柱脊髓杂志,2006,16(5):330-331. 被引量:42
  • 3陈开润,刘蜀生.腰椎椎弓根内部结构的解剖学研究[J].四川解剖学杂志,2007,15(3):26-28. 被引量:4
  • 4刘世敬,钟世镇,李佛保.儿童颈椎及脊髓损伤的研究进展[J].中国脊柱脊髓杂志,2007,17(11):875-877. 被引量:7
  • 5Resnick DK,Benzel EC. C1-C2 pedicle screw fixation with rigid cantilever beam construct:case report and technical note[J].{H}NEUROSURGERY,2002,(02):426-428.
  • 6Stulik J,Vyskocil T,Sebesta P. Atlantoaxial fixation using the polyaxial screw-rod system[J].{H}European Spine Journal,2007,(04):479-484.
  • 7Lapsiwala SB,Anderson PA,Oza A. Biomechanical comparison of four C1 to C2 rigid fixative techniques:anterior transarticular,posterior transarticular,C1 to C2 pedicle,and C1 to C2 intralaminar screws[J].{H}NEUROSURGERY,2006,(03):516-521.
  • 8Dickman CA,Sonntag VK. Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis[J].{H}NEUROSURGERY,1998,(02):275-280.
  • 9Richter M,Schmidt R,Claes L. Posterior atlantoaxial fixation:biomechanical in vitro comparison of six different techniques[J].Spine (Phila Pa 1976),2002,(16):1724-1732.
  • 10Deshmukh TR,Kuthe AM,Vaibhav B. Preplanning and simulation of surgery using rapid model ing[J].{H}Journal of Medical Engineering and Technology,2010,(04):291-294.

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部