摘要
阐述了S.Fryze功率理论,将金属氧化物避雷器泄漏电流分解为相互正交的有功分量与无功分量,研究了半波、全波、换流阀侧、换流桥侧、换流器侧等5种典型电压作用下金属氧化物避雷器有功电流的计算方法。
Based on the S. Fryze power theory, metal oxide varistor(MOV) leakage current is decomposed into mutu- ally orthogonal active and reactive components. Then algorithms for MOV active current were studied under five typi- cal voltages, namely, half wave, full wave, converter valve side, converter bridge side, and converter side.
出处
《华东电力》
北大核心
2012年第5期844-847,共4页
East China Electric Power
关键词
背靠背换流站
金属氧化物避雷器
氧化锌非线性电阻片
矢量正交分解法
有功电流
Back-to-Back ( BTB ) Converter Station
metal oxide varistor( MOV)
ZnO varistor
vector orthogonal de- composition
active current