摘要
本文对影响水平管薄膜蒸发过程的部分因素进行了模拟 ,确定了一定范围内水平管薄膜式蒸发器的总传热系数与液体负荷、不凝气含量、管内蒸气流速、传热温差的相应关系 。
The process of sea water desalnation with horizontal tube film evaporator was simulated and the influences of non-condensable gas content、film loading、temperature driving force, vapor flow rater and in the tubes on total heat transfer coefficiency were discussed. Providing the basis for the practical application of the desalination process.
出处
《水处理技术》
CAS
CSCD
2000年第2期90-92,共3页
Technology of Water Treatment
关键词
传热
水平管
降膜蒸发
脱盐
蒸发装置
海水淡化
heat transfer
horizontal tube
falling thin film evaporation
desalination