期刊文献+

大温差空调水系统在某商业项目中的应用 被引量:9

Application of large temperature difference water system in a commercial project
在线阅读 下载PDF
导出
摘要 以某商业项目空调水系统冷水及冷却水双侧大温差结合二次泵变频技术的应用为例,从末端设备、水泵、冷却塔、主机、管路等方面分析了空调系统设计流程和设备选择过程。比较了大温差系统和常规温差系统的耗电功率和初投资,验证了大温差技术在该项目应用中的可行性。 Taking the large temperature difference water system with variable secondary pumps as an example, in which to the both sides of chilled water and cooling water is applied the large temperature difference technique, presents the HVAC system design procedure and selection of equipment such as the terminal equipments, pumps, cooling towers, chillers and pipelines. Compares the system to the conventional system in power consumption and initial costs, and validates the feasibility of this technique in this project.
作者 高家绪 纵磊
出处 《暖通空调》 北大核心 2012年第7期93-98,77,共7页 Heating Ventilating & Air Conditioning
关键词 大温差 二次泵 变流量 节能 初投资 运行费用 large temperature, Secondary pump, variable flow, energy saving, initial cost, operating cost
  • 相关文献

参考文献2

二级参考文献14

  • 1霍小平.关于国外高层办公楼空调水系统大温差设计的探讨[J].暖通空调,1996,26(4):58-60. 被引量:16
  • 2佐藤正章 中村诚 著 周祖毅 译.关于大温差、小流量系统的分析和研究[J].空调暖通技术,1996,2:14-17,27.
  • 3石野裕嗣 佐藤正章 著 周祖毅 译.关于大温差、小流量系统的开发[J].空调暖通技术,1996,4:19-22.
  • 4A T Kirkpatrick, J S Elleson. Cold air distribution system design guide.Atlanta: ASHRAE inc. 1996.162~165
  • 5宋静,沈家水.上海儿童医学中心冰蓄冷技术的应用.见:全国暖通空调制冷1998年学术年会资料集,1998:385-387,358.
  • 6肖寰.对上海金茂大厦空调设计的认识.暖通空调新技术(第一辑).北京:中国建筑工业出版社,1999.
  • 7周祖毅.上海高层建筑空调设计新方法.见:殷平主编.空调设计(第二辑).长沙:湖南科技出版社,1998.
  • 8殷平.低温送风空调机组研制.见:全国暖通空调制冷1998年学术文集,1998:205-209.
  • 9殷平.多风机变风量空调系统及其应用.见:殷平主编.现代空调(第一辑).北京:中国建筑工业出版社,1999.
  • 10ASHRAE 1997.ASHRAE Handbook-Fundamentals. Atlanta:ASHRAE Inc.