期刊文献+

经皮钢板固定治疗胫骨远端骨折

Treatment of Distal Tibial Fractures Using Percutaneous Plate Osteosynthesis
在线阅读 下载PDF
导出
摘要 目的:介绍微创经皮插入接骨板内固定治疗胫骨远端骨折,并观察其效果。方法:采用闭合复位经皮插入接骨板内固定治疗胫骨远端骨折36例。AO分型:A型23例(A2型9例,A3型14例),B型9例,C型4例。术后不辅以其他外固定,第2天即开始不负重关节功能锻炼。结果:所有患者随访6~22个月,平均11个月。随访36例,所有病例伤口一期愈合。骨折无延迟愈合,无畸形愈合,平均临床愈合时间17周。根据Mazur的踝关节功能评分,优良率94.4%。结论:微创经皮插入接骨板内固定术是治疗胫骨远端骨折的有效方法。 Objective:To introduce minimally invasive percutaneous plate osteosynthesis(MIPPO) for the treatment of distal tibial fractures and investigate the results.Methods:36 cases of distal tibial fractures were treated with MIPPO.According to the AO classification,there were 23 cases of type A(9 type A2,14 type A3),9 type B and 4 type C.Without any external fixation,active and passive motion of ankle joint was allowed two days after operation without weight bearing.Results:All the patients were followed up for 6~22 months,11 months on average.Followed up 36 cases.The mean time of bone union was 17 weeks.No infection.Delayed union,nonunion or malunion was found in this Series.According to Mazur ankle joint function scoring,the excellent and good rate was 94.4%.Conclusion:MIPPO is a safe and effective technique in the treatment of distal tibial fracture.
出处 《医学理论与实践》 2012年第16期1953-1954,共2页 The Journal of Medical Theory and Practice
关键词 胫骨骨折 经皮插入钢板 骨折固定术 Tibia fractures MIPPO Fracture Fixation
  • 相关文献

参考文献6

二级参考文献15

  • 1王加宽,蒋建新,于晓雯.Pilon骨折的治疗[J].中华创伤骨科杂志,2003,5(1):26-28. 被引量:24
  • 2Perren SM. Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stabilit y and biological[J].J Bone Joint Surg (Br), 2002,84:1093-1110.
  • 3Krettek C. Concept of minimally invasive plate osteosynthesis[J].Injury, 1997,28: 805-809.
  • 4Payne SR,Ford TF,Wickham JE.Endoscopic management of upper urinary tract stones[J].Br J Surg,1985,72:822-824.
  • 5Safran O,Liebergall M,Segal D,et al.Proximal tibial fractures-should we nail them[J]?Am J Orthop,2001,30 (9):681-684.
  • 6Krettek C,Schandelmaier T,Miclau T,et al.Minmally invasive percutaneous plate osteosynthesis (MIPPO) using the DCS in proximal and distal femoral fractures[J].Injury,1997,28 (Suppl 1):A20-30.
  • 7Palmer RH.Biological osteosynthesis[J].Vet Clin North Am Small Anim Pract,1999,29:1171-1185.
  • 8Farouk O,Krettek C,Miclau T,et al.Minmally invasive percutaneous plate osteosynthesis:dose percutaneous plateing disrupt femoral blood supply less than the traditional technique?[J].J Orthop Trauma,1999,13:401-406.
  • 9Borg T,Larsson S,Lindsjo U.Percutaneous plating of distal tibial fractures preliminary results in 21 patients[J].Injury,2004, 35:608-614.
  • 10Schandelmaier T,Partenheimer A,Koenemann B,et al.Distal femoral fractures and LISS stabilization[J].Injury,2001,32:S-C-55-63.