期刊文献+

以1,3-二(4-邻羟基苯亚胺次甲基)苯氧基丙烷为载体的铁离子(Ⅲ)电极的研究

Study on a new iron(Ⅲ) selective electrode based 1,3-Bis(4-carbonyl-phenylimino-methine)isopropoxybenzene as a neutral carrier
在线阅读 下载PDF
导出
摘要 以1,3-二(4-邻羟基苯亚胺次甲基)苯氧基丙烷为中性载体制备了PVC膜Fe3+离子选择性电极。该电极对Fe3+呈现出良好的选择性和近Nernst电位响应性能。电极斜率为21mV/dec,线性范围为3.0×10-5~1.0×10-1mol/L,检出限为1.0×10-5mol/L。采用交流阻抗技术研究了电极的响应机理,并将电极作为指示电极初步用于EDTA的电位滴定。 A PVC membrane electrode for iron ( Ⅲ )ions based on 1,3-Bis (4-carbonyl- phenylimino-methine) isopropoxybenzene as a neutral carrier was investigated. The prepared electrode displays a good selectivity toward iron (m) and exhibits a near Nemstian response for iron (re)over a linear range of 3.0×10^-5-1.0×10^-1mol/L with a detection limit of 1.0×10^-5 mol/L and a slope of 21 mV/dec. The electrode was used as an indicator electrode in potentiometric titration of iron(Ⅲ) with EDTA with satisfactory results.
出处 《化学传感器》 CAS 2012年第2期31-34,共4页 Chemical Sensors
基金 国家自然科学基金资助项目(21075100)资助
关键词 1 3-二(4-邻羟基苯亚胺次甲基)苯氧基丙烷 PVC膜 铁离子选择性电极 1,3-Bis(4-carbonyl-phenylimino-methine)isopropoxybenzene PVC membrane iron(Ⅲ )selective electrode
  • 相关文献

参考文献14

  • 1吴惠刚,黄诚,高昶,冯银凤.电热原子吸收光谱法测定生活饮用水中的铁[J].中国卫生检验杂志,2005,15(5):570-570. 被引量:3
  • 2Chandra S, Singh D R. Polymeric membrane neodymium(Ⅲ)-selective electrode based on 11,13-diaza-4, 7, 12- trioxo-2(3), 8(9)-dibenzoyl- cyclotetridecane-1, 1 1-di- ene [J]. Mat. Sci. Eng. A., 2009, 502: 107-110.
  • 3Mashhadizadeh M H, Sheikh S I, Monadi N. A novel ion selective membrane potentiometric sensor for direct de- termination of Fe(m) in the presence of Fe( Ⅱ) [J]. Ta- lanta, 2004, 64:1 048-1 052.
  • 4Zamani H A, Ganjali M R, Behmadi H, et al. Fabrication of an iron (Ⅲ) PVC membrane sensor based on bis-ben- zihhiocarbohydrazide as a selective sensing material [J]. Mat. Sci. Eng. C., 2009, 29:1 535 - 1 539.
  • 5Oliverra A F, Nobrega J A, Fatibello F O. Asynchronous merging zones system: spectrophotometric determination of Fe( Ⅱ ) and Fe(Ⅲ) in pharmaceutical products [J ]. Ta- lanta, 1999, 49:505 -510.
  • 6Koryta J. Theory and applications of ion-selective elec- trode [J]. Anal. Chim. Acta., 1990, 233:1-30.
  • 7Costa R C C, Araujo A N. Determination of Fe (Ⅲ) and total Fe in wines by sequential injection analysis and flame atomic absorption spectrometry [J]. Anal. Chim. Acta., 2001, 438: 227-233.
  • 8Safavi A, Abdollahi H, Hormozi N M R. Simultaneous ki- netic determination of Fe (Ⅲ) and Fe ( Ⅱ ) by H-point standard addition method [J]. Talanta, 2002, 56: 699- 704.
  • 9Mahmoud W H. Iron ion-selective electrodes for direct potentiometry and potentiotitrimetry in pharmaceuticals [J]. Anal. Chim. Acta, 2001, 436: 199-206.
  • 10Wu J, Boyle E A. Determination of iron in seawater by high-resolutionisotope isotope dilution inductively cou- pled plasma mass spectrometry after Mg(OH)2 coprecipi- tation [J]. Anal. Chim. Acta., 1998, 367: 183-191.

二级参考文献1