摘要 目的 :应用多普勒超声检测经颈静脉肝内门体静脉支架分流术(Transjugular intrahepatic portosystemic stentshunt,TIPSS)术后内支架及其血流情况,包括正常、狭窄和闭塞,探讨多普勒超声在TIPSS术后随访中的价值。方法:32例肝硬化门脉高压患者行TIPSS,术后多普勒超声检查86例次,包括支架内的血流、门静脉和脾静脉的血流方向和速度。结果:随访时间为8月~3年,二维超声清晰显示TIPSS内支架的网状回声,彩色多普勒和能量多普勒显示支架内的血流方向,频谱多普勒显示支架内以及门静脉和脾静脉的血流速度。其中5例病人多普勒血流显示支架内狭窄,支架门静脉端和肝静脉端血流速度减慢,支架内狭窄处为高速湍流。门静脉及脾静脉速度明显降低,为门静脉造影所证实。与非狭窄支架组比较,狭窄支架的血流速度测值差异有显著性意义(P〈0.05)。结论:多普勒超声可以方便有效地检测TIPSS术后内支架的血流情况及早期发现分流道的狭窄,是TIPSS术后定期复查和疗效判断的首选方法。
出处 《中国临床医学影像杂志》 CAS 2012年第8期591-593,共3页 Journal of China Clinic Medical Imaging
  • 相关文献

参考文献5

  • 1Rossle M, Grandt D. TIPS: an update [J]. Best Pract Res Clin Gastroenterol, 2004, 18(1): 99-123.
  • 2Libicher M, Radeleff B, Madler U, et al. After-care of TIPSS patients. Comparison between color Doppler ultrasound and por- tography[J]. Radiologe, 1998, 38(5): 370-377.
  • 3Bodner G, Peer S, Kreczy A, et al. Results of doppler sortogra- phy in normally functioning transjugular portosystemic shunts[J]. Ultraschall Med, 2000, 21(4): 160-164.
  • 4季正标,黄备建,丁红,罗剑钧,王文平.探讨彩色多普勒超声在TIPSS术后随访中的作用[J].中国超声医学杂志,2004,20(9):688-690. 被引量:6
  • 5Kliewer MA, Hertzberg BS, Heneghan JP, et al. Transjugular in- trahepatic portosystemic shunts (TIPS): effects of respiratory state and patient position on the measurement of Doppler velocities[J]. AJR, 2000, 175(1): 149-152.

二级参考文献9

  • 1刘明辉.经颈静脉肝内门-腔静脉支架放置术的彩色多普勒超声成像[J].国外医学(临床放射学分册),1996,19(5):271-273. 被引量:2
  • 2Furst G,Malms J,Heyer T,et al.Transjugular intrahepatic portos-ystemic shun ts:improved evaluation with echo-enhanced color Doppler sonography,power Doppler sonography,and spectral duplex sonography.Am J Roentgenol 1998,170 (4):1 047 -1 054
  • 3Foshager MC,Ferral H,Finlay DE,et al.Color Doppler sonography of transjugular intrahepatic portosystemic shunts (TIPS).AJR,1994,163(1):105-111
  • 4Dodd GD,Zajko AB,Orons PD,et al.Detection of transjugular intrahepatic porto systemic shunt dysfunction:value of duplex Doppler sonography.AJR,1995,164:1 11 9-1 124
  • 5Longo JM,Bibao JI,Rousseau HP,et al.Transjugular intrahepatic portosystemic shunt:evaluation with Doppler sonogra-phy.Radiology,1993,186:529-534
  • 6Foshager MC,Ferral H,Nzazrian GK,et al.Duplex sonography after transjugular intrahepatic portosystemic shunt(TIPS):normal hemodynamic findings and efficacy in predicting shunt patency and stenosis.AJR,1995,165:1-7
  • 7Bodner G,Peer S,Fries D,et al.Color and pulsed Doppler ultraso-und findings in normally functioning transjugular intrahepatic portosystemic shunts.Eur J U ltrasound 2000,12(2):131-137
  • 8Uggowitzer MM,Kugler C,Machan L,et al.Value of echo-enhanced Doppler sonogr aphy in evaluation of transjugular intrahepatic portosystemic shunts.Am J Roent genol 1998,170(4):1 041-1 046
  • 9吴凤林,龚渭冰,李彦豪.彩色多普勒超声检测TIPSS术后肝内支架血流[J].中华超声影像学杂志,1998,7(2):76-80. 被引量:7

共引文献5

同被引文献85

引证文献11

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部