期刊文献+

风电系统网侧LCL滤波器的分析与参数设计 被引量:1

Analysis of the Network Side LCL Filter in a Wind Power System and its Parameters Design
在线阅读 下载PDF
导出
摘要 针对风力发电系统中频繁用到的并网LCL滤波器,分析LCL滤波器参数的特性,提出限制条件,给出计算公式,分析了滤波电容加阻尼电阻对系统性能的影响。仿真结果表明,设计的LCL滤波器滤波效果较好,验证了理论分析的正确性。 LCL filter was frequently used in wind power parallel systems.This paper analyzed LCL filter parameter characteristics,proposed limiting conditions and the calculation formulas,at the same time,discussed a filter capacitor and resistor damping effects on system performance.The simulation results show that the designed LCL filter had good performance,and therefore,verified the correctness of the theoretical analysis.
作者 张蓉 唐婷
出处 《成都电子机械高等专科学校学报》 2012年第3期28-31,共4页 Journal of Chengdu Electromechanical College
关键词 LCL滤波器 三相电压型PWM变流器 谐振频率 开关频率 谐波 LCL filter three-phase voltage type PWM rectifier resonant frequency switching frequency harmonic
  • 相关文献

参考文献5

二级参考文献39

  • 1赵仁德,贺益康,刘其辉.提高PWM整流器抗负载扰动性能研究[J].电工技术学报,2004,19(8):67-72. 被引量:68
  • 2伍小杰,罗悦华,乔树通.三相电压型PWM整流器控制技术综述[J].电工技术学报,2005,20(12):7-12. 被引量:112
  • 3Marco Liserre , Remus Teodorescu , Frede Blaabjerg. Stability of Photovoltaic and Wind Turbine Grid - connected Inverters for a Large Set of Grid Impedance Values [ J ]. IEEE Transactions on Power Electronics, 2006,21(1):263-272
  • 4Fainan A Magueed , Jan Svensson . Control of VSC Connected to the Grid Through LCL - filter to Achieve Balanced Currents [ C]. Industry Applications Conference , Fourtieth IAS Annual Meeting, 2005,1 : 572 - 578
  • 5Mariusz Mainowski , Steffen Bernet. Simple Control Scheme of PWM Converter Connecting Wind Turbine with Grid - simulation Study [ C ] . Nordic Wind Po - wer Conference , Chalmers University of Technology, 2004 : 1 - 4
  • 6Blaabjerg F, Chiarantoni E, Dell Aquila etal . Analysis of the Grid Side Behavior of a LCL - filter Based Three- phase Active Rectifier [ J ]. Industrial Electronics, IEEEInternationalSymposium, 2003,2 : 775- 780
  • 7Marco Liserre , Frede Blaabjerg , Steffan Hansen. Design and Control of an LCL - filter - based Three - phase Active Rectifier [ J ] . IEEE Transactions on Industry Applications, 2005,41(5):1 281-1 290
  • 8Bojrup M . Advanced Control of Active Filters in a Battery Charger Application[D]. ph.D. Dissertation, Lund Univ. Technol. , Lund, Sweden, 1999
  • 9Lang Yongqiang , Xu Dianguo , Hadianamrei S R. A Novel Design Method of LCL Type Utility Interface for Three- phase Voltage Source Rectifier [ C ]. Power Electronics Specialists,IEEE 36th Conference, 2005 : 313-317
  • 10Vladimir Blasko , Vikram Kaura. A Novel Control to Actively Damp Resonance in Input LC Filter of a Three- phase Voltage Source Converter [ J ]. IEEE Transactions on Industry Application, 33(2):542-550

共引文献75