期刊文献+

腕表式睡眠监测仪对睡眠呼吸暂停低通气综合征诊断作用的研究

Evaluation of Watch PAT as a diagnosing test for patients with obstructive sleep apnea hypopnea syndrome
原文传递
导出
摘要 目的检验腕表式睡眠监测仪(watch peripheral arterial tone,Watch PAT)诊断睡眠呼吸暂停低通气综合征(OSAHS)的准确性及其影响因素。方法35例以睡眠打鼾为主诉的门诊患者同时行Watch PAT监测和多道睡眠监测(PSG)。PSG监测的结果由同一位有经验的技师人工分析,Watch PAT的结果则由软件自动分析。结果35例研究对象PSG的睡眠呼吸暂停低通气指数(AHI)有高于Watch PAT AHI的趋势(P=0.06),但两者之间相关性较好,相关系数(r)可达0.955(P〈0.001)。通过Watch PAT的AHI来预测PSG AHI的线性回归得到的结果为AHI(PSG)=0.944+1.030AHI(Watch PAT),P〈0.001。以PSG监测的AHII〉5次/h做为OSAHS的诊断标准,利用ROC曲线考察Watch PAT的诊断效率,所得到的曲线下面积可达0.953(P〈0.001);以Watch PAT监测的AHI值8.65次/h作为界值,诊断的敏感性和特异性分别为92.3%和100.0%。以AHI(Watch PAT)和AHI(PSG)差值绝对值作为分组标准,差值≥5次/h患者的体质量指数(BMI)有大于差值〈5次/h患者BMI的趋势(P=0.077)。结论Watch PAT诊断OSAHS有较高的准确性,可以作为诊断OSAHS的一种简单可靠的检测工具,但对于BMI较大的患者其诊断的准确性可能较差。 Objective This study aimed to test the accuracy of the watch peripheral arterial tone (Watch PAT) in diagnosing the obstructive sleep apnea hypopnea syndrome (OSAHS) and its influencing factors. Methods Thirty five outpatients who had a chief complaining of sleep snoring were recruited to receive Watch PAT test and polysomnography (PSG) simultaneously. The results of PSG were manually analyzed by an experienced technician, while the results of Watch PAT were automatically analyzed by software. Results There was a trend that the apnea hypopnea index (AHI) of PSG was significantly higher than that of Watch PAT (P = 0.06 ) in the 35 patients studied, however, these two variables were significantly correlated ( P 〈 0. 001 ), and the correlation coefficient was as high as 0. 955. A linear regression analysis which used the AHI of Watch PAT to predict the AHI of PSG also concluded same result and the equation was AHI(PSG) = 0. 944 + 1. 030AHI( Watch PAT), P 〈 0. 001. The analysis which used ROC curve to test the diagnostic efficiency of Watch PAT concluded that the area under the curve could reach to 0, 953 (P 〈0. 001 ), and if an AHI (Watch PAT) threshold of≥8. 65 was used as the cut-off point in this study, the sensitivity and specificity could reach to 92. 3% and 100. 0%. The absolute values of the differences (AVD) between the AHI of Watch PAT and the AHI of PSG were also calculated as a criterion for grouping the 35 patients studied, then it could be found that there was a trend that the BMI of patients who had an AVD≥5 were higher than that of patients who had an AVD 〈 5 (P = 0. 077 ). Conclusions The Watch PAT is highly sensitive in the diagnosis of OSAHS, it can be used as a simple and reliable method for screening people with suspicious OSAHS. However, the accuracy of diagnosis may be relatively low in patients who have a great BMI.
出处 《中华耳鼻咽喉头颈外科杂志》 CAS CSCD 北大核心 2012年第10期813-816,共4页 Chinese Journal of Otorhinolaryngology Head and Neck Surgery
关键词 睡眠呼吸暂停 阻塞性 多道睡眠描记术 监测 便携式 打鼾 Sleep apnea obstructive Polysomnography Monitoring, ambulatory Snoring
  • 相关文献

参考文献17

  • 1Gross JB, Bachenberg KL, Benumof JL, et al. Practice guidelinesfor the perioperative management of patients with obstructive sleepapnea : a report by the American Society of Anesthesiologists TaskForce on Perioperative Management of patients with obstructivesleep apnea. Anesthesiology, 2006,104 : 1081-1093.
  • 2Gali B, Whalen FX, Schroeder DR, et al. Identification ofpatients at risk for postoperative respiratory complications using apreoperative obstructive sleep apnea screening tool andpostanesthesia care assessment. Anesthesiology, 2009 , 110 : 869-877.
  • 3高宇红,薛毅珑,罗芸,崔忻,田磊,潘静坤,杨军.应用床垫式睡眠监测系统检出睡眠呼吸暂停综合征的200例临床分析[J].临床肺科杂志,2010,15(4):555-556. 被引量:6
  • 4Lin CM, Davidson TM, Ancoli-Israel S. Gender differences inobstructive sleep apnea and treatment implications. Sleep MedRev, 2008’ 12: 48M96.
  • 5L6vy P, Pepin JL, Deschaux-Blanc C, et al. Accuracy ofoximetry for detection of respiratory disturbances in sleep apneasyndrome. Chest, 1996, 109 : 395-399.
  • 6Somers VK,Dyken ME, Clary MP, et al. Sympathetic neuralmechanisms in obstructive sleep apnea. J Clin Invest, 1995,96:1897-1904.
  • 7Bar A, Pillar G,Dvir I,et al. Evaluation of a portable devicebased on peripheral arterial tone for unattended home sleepstudies. Chest, 2003, 123: 695-703.
  • 8Grote L,Zou D, Kraiczi H, et al. Finger plethysmography-amethod for monitoring finger blood flow during sleep disorderedbreathing. Respir Physiol Neurobiol, 2003 , 136 : 141-152.
  • 9Grote L,Kraiczi H,Hedner J. Reduced alpha- and beta (2)-adrenergic vascular response in patients with obstructive sleepapnea. Am J Respir Crit Care Med, 2000 , 162 : 1480-1487.
  • 10Laurent S, Cockcroft J, Van Bortel L, et al. Expert consensusdocument on arterial stiffness : methodological issues and clinicalapplications. Eur Heart J,2006, 27 : 2588-2605.

二级参考文献42

  • 1李永霞,海冰,钟红.阻塞性睡眠呼吸暂停低通气综合征与高血压[J].临床肺科杂志,2004,9(6):638-639. 被引量:18
  • 2俞梦孙,杨军,张宏金,赵显亮,王宏山,成奇名.床垫式低负荷睡眠检测技术的临床应用[J].实用诊断与治疗杂志,2004,18(6):469-471. 被引量:15
  • 3敖华飞,郭竹英,高尚.阻塞性睡眠呼吸暂停低通气综合征病人手术前后血中炎性因子的变化[J].中国耳鼻咽喉颅底外科杂志,2006,12(5):368-370. 被引量:15
  • 4曹惠芳,张萍,杨蓓琳.阻塞性睡眠呼吸暂停综合征患者的血氧饱和度和肺功能变化[J].临床肺科杂志,2007,12(4):349-351. 被引量:10
  • 5Rech tschaffen A, Kales A. A manual of standardized term inology, techniques and scoring system for sleep stages of human subjects. Los angeles: UCLA Brain Infonnation Service/Brain Research Institute, 1968.
  • 6Choi JH, Kim E J, Kim YS, et al. Validation study of portable device for the diagnosis of obstructive sleep apnea according to the new AASM scoring criteria: Watch-PAT 100. Acta Otolaryngol, 2010, 130: 838-843.
  • 7Pang KP, Gourin CG, Terris DJ. A comparison of polysomnography and the Watch PAT in the diagnosis of obstructive sleep apnea. Otolaryngol Head Neck Surg, 2007, 137: 665-668.
  • 8Zou D, Grote L, Peker Y, et al. Validatiion a portable monitoring device for sleep apnea diagnosis in a populatiion based cohort using synchronized home polysomnography. Sleep, 2006, 29: 367-374.
  • 9中华医学会耳鼻咽喉科分会 中华耳鼻咽喉科杂志编委会.阻塞型睡眠呼吸暂停低通气综合征诊断依据和疗效判定标准暨悬雍垂腭咽成形术适应证(杭州)[J].中华耳鼻咽喉科杂志,2002,.
  • 10Collop NA, Anderson WM, Boehlecke B, et al. Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable monitoring task force of the American Academy of sleep medicine. J Clin Sleep Med, 2007, 3: 737-747.

共引文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部