期刊文献+

An experimental and numerical study on the charring rate of timber beams exposed to three-side fire 被引量:10

An experimental and numerical study on the charring rate of timber beams exposed to three-side fire
原文传递
导出
摘要 To investigate the charring rate of timber beams exposed to three-side fire, a total of fifteen new and used Douglas-Fir timber beams in four groups exposed to three-side fire were experimentally studied, together with the finite element analyses of the temperature distribution in the beam section. The durations of fire exposure were 0 (on a test piece), 10, 15, 20 and 30 min, according to the ISO 834 standard fire curve. The charring depth of each timber beam was calculated by averaging the values at one-third and two-thirds along each cross section to give the charring rate of timber beams. It was found that the timber beam's charring rate reduces as the duration of fire exposure increases and the vertical charring rate is slightly higher than the horizontal one. The areas of beam sections reduce due to charring and the strength and stiffness of the pyrolysis layer near the charring edge decrease owing to the high-temperature. The average horizontal and vertical charring rates are 0.98 and 1.08 mm/min, respectively. To take into account the difference between the test furnace temperature curve and the ISO 834 stand- ard fire curve, some corrections were made for these data to yield the solution for charring rate. With the help of the finite element software ANSYS, the temperature distribution of the wood's cross-section was analyzed. The longer the exposure time is, the greater the effect of density will impose on the distribution of temperature, but the moisture content has no effect.
出处 《Science China(Technological Sciences)》 SCIE EI CAS 2012年第12期3434-3444,共11页 中国科学(技术科学英文版)
基金 supported by the National Natural Science Foundation of China (Grant No. 51178115) the Priority Academic Program Development of Jiangsu Higher Education Institutions
关键词 timber beam charring rate exposed to three-sides fire charring layer pyrolysis layer 炭化 火灾 木梁 木材 数值模拟 实验 温度分布 温度曲线
  • 相关文献

参考文献5

二级参考文献41

  • 1薛建阳,赵鸿铁,张鹏程.中国古建筑木结构模型的振动台试验研究[J].土木工程学报,2004,37(6):6-11. 被引量:79
  • 2王小彦.地板木阻燃技术及其应用[J].无机盐工业,1995,9(4):26-28. 被引量:2
  • 3陈波.木结构建筑防火初探[J].大众科技,2006,8(7):21-21. 被引量:3
  • 4姚侃,赵鸿铁,葛鸿鹏.古建木结构榫卯连接特性的试验研究[J].工程力学,2006,23(10):168-173. 被引量:162
  • 5YOUNG S, CLANCY P. Compression mechanical properties of wood at temperatures simulating fire condltlon[J]. Fire and Materials, 2001, 25(2) :83-93.
  • 6LIE T. A method for assessing the fire resistance of laminated timber beams and columns[J]. Canadian Journal of Civil Engineering, 1977, 4(2) : 161-169.
  • 7National Building Code of Canada. Canadian Commission on Building and Fire Codes[S]. Ottawa, Ontario, 1995.
  • 8Technical Report 10, Calculating the fire resistance of exposed wood members[R]. AF & PA, 2003.
  • 9EN 1995-1-2 : 2004, Eurocode 5 : Design of timber structures [ S ]. Part 1-2: general-structural fire design.
  • 10WHITE R. Fire resistance of exposed wood member[C]//Wood & fire safety, Proceedings of 5th International Scientific Conference, 2004: 337-344.