期刊文献+

电力电缆故障数据的统计模型分析 被引量:5

Statistical model analysis of cable failure data
原文传递
导出
摘要 建立了Weibull分布和Crow-AMSAA模型用来分析电缆故障数据以预测电缆故障率和指导维修更换;数学推导表明,两参数Weibull分布和Crow-AMSAA模型的表达式具有一致性,Crow-AMSAA模型是一种特殊形式的两参数Weibull分布.对比Weibull分布和Crow-AMSAA模型对某供电公司电缆8年故障数据的分析结果表明,Weibull分布可定性分析失效时间,可以得到故障的模式;Crow-AMSAA模型可定量分析累积故障次数和累积故障时间,可预测未来故障次数;当故障数据样本较小时,Weibull分布的分析结果相对准确. This paper has built Weibull distribution and Crow-AMSAA model to analyse the power cable failure data so as to predict the failure rate.It is found through the mathematical deduction that the Crow-AMSAA model is a special form of the two parameters Weibull distribution.By using Weibull distribution and Crow-AMSAA model,the analysis results of 8 years failure data of a power supply company are compared.It is found that the Weibull distribution is qualitative in nature.It uses age to failure data as input,from which failure model can be obtained.In comparison,the Crow-AMSAA model is quantitative.It takes on cumulative time vs cumulative faults data from which the future number of failure can be acquired.When the size of failure data sample is small,the result of Weibull distribution is more reliable.
出处 《武汉大学学报(工学版)》 CAS CSCD 北大核心 2012年第5期667-672,共6页 Engineering Journal of Wuhan University
基金 Engineering and Physical Sciences Research Council(UK)(EP/G028397/1)
关键词 电力电缆 WEIBULL分布 Crow-AMSAA模型 电缆故障 小样本 power cable Weibull distribution Crow-AMSAA model cable fault small sample
  • 相关文献

参考文献24

二级参考文献124

共引文献211

同被引文献40

  • 1李华春,周作春,陈平.110 kV及以上高压交联电缆系统故障分析[J].电力设备,2004,5(8):9-13. 被引量:45
  • 2王玲玲,王炳兴.无失效数据的统计分析—修正似然函数方法[J].数理统计与应用概率,1996,11(1):64-70. 被引量:57
  • 3Wenyuan Li. Evaluating mean life of power system equip- ment with limited end-of-life failure data [J]. IEEE Trans. on Power Systems, 2004, 19( 1 ) : 236-242.
  • 4Wenyuan Li, Jiaqi Zhou, Jiping Lu et al. A Probabilistic Analysis Approach to Making Decision on Retirement of Aged Equipment in Transmission Systems [J]. IEEE Trans. on Power Delivery, 2007,22 (3): 1891-1896.
  • 5Lee W S, Grosh D L, Tillman F A, et al. Fault Tree Analy- sis, Methods, and Applications, A Re,Aew [J]. IEEE Trans. on Reliability, 1985, R-34 (3): 194-203.
  • 6Wang Kai, Deng Yurong, Zhu Shiyang, et al. Safety risk analysis of insulators in electric transmis- sion line based on fuzzy fault tree method [C]. International Conference on Condition Monitoring and Diagnosis, Bali, Indonesia, 2012:941-945.
  • 7Agarwal S S, Kansal M L. Fuzzy fault tree analysis of a pow- er transformer [C].International Conference on proceedings of the Quality, Reliability, Risk, Maintenance, and Safety Engineering, 2012: 1000-1004.
  • 8Wenyuan Li. Risk assessment of power systems: models, methods, and applications [M]. New York. John Wiley & Sons, 2014.
  • 9Q/CSG11099-2010,110kV-500kVSF.断路器状态评价导则[S].
  • 10白恺,罗日成.输变电设备风险评估[J].中国电力,2009,42(10):48-51. 被引量:15

引证文献5

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部