摘要
本文对大唐三门峡发电有限责任公司两台600MW超临界机组配套美国CCI公司生产的HBSE160-250型高压旁路阀内漏原因进行了详尽分析,提出了彻底消除高旁内漏的解决措施。对选用该型号高旁阀且内漏的机组都有很好的借鉴意义。
In this paper,Datang Power Generation Co. Ltd Sanmenxia two 600MW supercritical unit supporting the U.S. CCI produced HBSE 160-250 high-pressure bypass valve leakage cause a detailed analysis,the complete elimination of leakage within the high-side solutions.The model of choice within the high side valve and drain the unit has a good reference.
出处
《河南电力》
2012年第2期43-45,共3页
Henan Electric Power
关键词
汽轮机
高压旁路阀
内漏
分析处理
high pressure turbine
bypass valve
leakage
analysis and processing