期刊文献+

测定化探样品中痕量钒的流动注射光泽精化学发光法 被引量:6

Determination of Trace Vanadium in Geochemical Exploratory Samples by Flow Injection Chemiluminescence Analysis
在线阅读 下载PDF
导出
摘要 用配有Jones还原器的流动注射系统,研究了光泽精与钒(Ⅱ)的化学发光反应,并建立了钒的流动注射化学发光分析法。该法线性范围为1×10-6~1×10-2 g/L ,检出限为3×10-7 g/L,相对标准偏差为2.0 %(1×10-4 g/L,n=11),相关系数在0.9988以上。已用于化探样品中痕量钒的测定,结果令人满意。 A flow injection chemiluminescence method for the determination of trace vanadium based on the reaction between lucigenin and V(Ⅱ) generated by Jones reductor is described. The present method has a wide linear range of 1×10-6~1×10-2 g/L for vanadium with correlation coefficients≥0.998 8. The relative standard deviation is 2.0%(1×10-4 g/L, n=11). The detection limit is 3×10-7 g/L. The method has been used to determine vanadium in geochemical exploratory samples with satisfactory results. The method is found to be simple, convenient, precise and accurate.
作者 朱智甲
出处 《分析测试学报》 CAS CSCD 2000年第4期76-78,共3页 Journal of Instrumental Analysis
关键词 光泽精 化探样品 痕量分析 化学发光法 Flow injection Chemiluminescence analysis Lucigenin Vanadium
  • 相关文献

参考文献3

二级参考文献10

  • 1杨晓云,尹家元,周中万,徐其亨.二安替比林甲烷芳环衍生物的合成及其光度性质的研究[J].化学试剂,1993,15(3):146-148. 被引量:28
  • 2杨晓云,周中万,徐其亨.二安替比林基氯代苯基甲烷与钒(V)显色反应的研究[J].分析化学,1994,22(1):44-46. 被引量:29
  • 3慈云祥,分析试验室,1989年,8卷,2期,15页
  • 4吕九如,化学学报,1984年,42卷,562页
  • 5李益新,生物化学与生物物理学报,1983年,2卷,59页
  • 6禹济民,分析化学,1988年,16卷,11期,1030页
  • 7赵晨曦,硕士学位论文,1988年
  • 8徐其亨,阮琼.在吐温40和锰(Ⅱ)存在下二安替比林苯乙烯基甲烷与钒(Ⅴ)显色反应的研究[J]分析化学,1988(04).
  • 9潘教麦,裴立文,徐钟隽.二安替比林苯乙烯基甲烷的纯化及其氧化反应的研究[J]化学试剂,1987(03).
  • 10章道昆,萨燕平.锰存在下用二安替比林苯乙烯甲烷分光光度法测定矿石中的微量钒(Ⅴ)[J]化学试剂,1985(05).

共引文献14

同被引文献138

  • 1孙杰,毛东森,张国莹,陈同岳.流动注射pH梯度技术-多元线性回归法同时测定相互干扰的两组份[J].分析试验室,1993,12(6):19-22. 被引量:5
  • 2颜晓梅,王小茹,杨芃原,杭纬,黄本立.多道ICP-AES与瞬时进样技术在线联用的信号采集和处理[J].高等学校化学学报,1993,14(11):1506-1509. 被引量:8
  • 3章竹君,王军锋.流动注射光纤荧光探针动力学法测定铁的研究[J].高等学校化学学报,1996,17(4):535-538. 被引量:6
  • 4[1]Ruzicka J,Hansen E H.FlowInjectionAnalysis(2nd Ed)[M].NewYork:John Wiley&Sons,1988
  • 5[2]Garrigues S,Galliguan M.Simultaneous determination of ortho-,meta-and para-xylene by flow injection-fourier transform infrared spectroscopy[J].The Analyst,1992,(117):1849
  • 6[3]Ruzicka J,Arndal A.Sorbent extraction in flow injection analysis and its application to enhancement of atomic spectrometry [J].Anal.Chim.Acta,1989,(216):243
  • 7[4]Fang Z,Guo T,Welz B.Determination of cadmium,lead and copper in water samples by flame atomic absorption spectrometry with preconcentration by flow-injection on-line sorbent extraction[J].Talanta,1991,38(6):613
  • 8[5]Sperlin M,Yin X,Welz B.Differential determination of chromium(VI) and total chromium in natural waters using flow injection on-line separation and preconcentration electrothermal atomic absorption spectrometry[J].The Anelyst,1992,(117):629
  • 9[6]Ali A.,Yin Xuefeng,Hong Shen,et al.1,10-Phenanthroline as a complexing agent for on-line sorbent extraction/preconcentration for flow injection-flame atomic absorption spectrometry[J].Anal Chim.Acta,1999,(392):283
  • 10[10]Heichmar E M,Hinners T A.Minimization of interferences in inductively coupled plasma mass spectrometry using on-line preconcentration[J].Anal.Chem.,1990,62 (8):857

引证文献6

二级引证文献37

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部