期刊文献+

羊水指数测定用于产前监护的价值 被引量:4

The value of amniotic fluid index in antepartum monitoring
在线阅读 下载PDF
导出
摘要 目的评价羊水指数 (AFI)在产前监护中的价值。方法研究 1998年 1月至 1999年 12月于我院进行产前羊水指数测定的 2 881例孕妇资料 ,就其中单胎、足月、无妊娠并发症和合并症 ,且于分娩前 1周内行AFI测定的 45 1例进行分析。AFI≤ 5 0mm、5 1~ 80mm和 >80mm分别为羊水过少、羊水偏少 (警戒值 )、羊水正常的标准。分别对三组围产儿结局进行比较。结果AFI≤ 5 0mm组不良结局围产儿较其余两组明显增加 (P <0 0 5 ) ;AFI =5 1~ 80mm与 >80mm组比较 ,P >0 0 5。提示AFI与AFD均可用于羊水过少的监测 ,但AFI具有更高的敏感性和特异性。结论AFI可用于羊水量的监测 ,同时可作为胎儿及新生儿预后的早期监测指标 ;AFI≤ 5 0mm常预示羊水过少和胎儿预后不良。 Objective [WT5”BZ]To evaluate the value of AFI in antepartum monitoring.Methods[WT5”BZ] A retrospective review of all patients with entering antepartum examination was carried out at our hospital from January,1998 to December,1999.There were 451 women with singleton pregnancies,≥37 weeks'gestation and without complication,who underwent antepartum testing within l week of delivery and who were delivered at our institution were identified for our study.Amniotic fluid index(AFI)≤50mm was defined as oligohydramnios,AFI>80mm was considered normal and AFI of 51~80mm was reputed as “borderline”.[WT5”HZ]Results [WT5”BZ]There was a significantly increased incidence of adverse perinatal outcome (included intrapartum fetal distress,5 minute Apgar score <7,meconium-stained amniotic fluid intrauterine growth restriction and late decelerations) among the gravida with AFI≤50mm in comparison with AFI=51~80mm and AFI>80mm( P <0 05).There was no difference in perinatal outcome between AFI>80mm and AFI=51~80mm.The AFI and AFD have been used to assess the amniotic fluid.AFI has been validated as an accurate technique for it has a higher sensitivity and peculiarity than AFD.Conclusion The AFI has been validated as an accurate and reproducible technique for assessment of amniotic fluid volume and an early marker of perinatal outcome.AFI≤50mm was associated with oligohydramnios and adverse perinatal outcome.
出处 《贵州医药》 CAS 2000年第10期587-590,共4页 Guizhou Medical Journal
关键词 羊水指数 羊水过少 产前监测 Amniotic fluid index Oligohydramnios Antepartum monitoring
  • 相关文献

参考文献9

  • 1Banks EH,Miller DA.Perinatal risks associted with border-line amniotic fluid index. Am J Obstet Gynecol ,1999,180:1461~1463.
  • 2卢丽萍,曲陆荣,丛杰,卢杰平.胎儿肾、脑动脉血流参数和羊水指数与围产儿预后的关系[J].中国医科大学学报,1998,27(4):413-414. 被引量:1
  • 3Rutherflord SE, Phelan JP, Smith CV, et al. The fourquadrant assessment of amniotic fluid volume: an adjunct to antepartum fetal heart rate testng. Obstet Gynecol, 1987,70:353~356.
  • 4Manning FA, Harman CR, Morrison Ⅰ, et al. Fetal assessment based on fetal biophysical profile scoring. Ⅳ. An analysis of perinatal morbidity and mortality. Am J Obstet Gynecol, 1990,162:703~709.
  • 5Chamberlain PF, Manning FA, Morrison Ⅰ, et al. Ultrasound evaluation of amniotic fluid volume. Ⅰ. The relationship of marginal and decreased amniotic fluid volumes to perinatal outcome. Am J Obstet Gynecol, 1984,150:245~249.
  • 6罗喜平,黄艳仪,梁瑞霞,陈小兵.B超诊断羊水偏少孕妇阴道试产196例分析[J].中华妇产科杂志,1998,33(10):585-587. 被引量:21
  • 7Phelan,JP, Smith CV, Broussard P, et al. Amniotic fluid volume assessment with the four-quadrant technique at 36~42 weeks'gestation. J Reprod Med, 1987,32:540~542.
  • 8Garmel SH, Chelmow D, Sha SJ, et al. Oligohydramnios and the appropriately grown fetus. Am J Perinatol, 1997,14: 359~363.
  • 9Low JA. The current stalus of maternal and fetal blood flow velocimetry. Am J Obstet Gynecol, 1991,164:1049~1057.

二级参考文献8

  • 1李笑天,庄依亮,张珏华,张振钧.胎儿血流速度波形预测围产儿预后的价值[J].中华妇产科杂志,1995,30(1):22-26. 被引量:28
  • 2易家君,江苏医药,1994年,20卷,250页
  • 3张志诚,临床产科学,1994年,215页
  • 4谯淑平,实用妇产科杂志,1992年,8卷,137页
  • 5吴乾渝,实用妇产科杂志,1992年,8卷,83页
  • 6戴钟英,实用妇产科杂志,1989年,5卷,302页
  • 7黄敏丽,实用妇产科杂志,1989年,5卷,71页
  • 8曹斌融,中华妇产科杂志,1982年,17卷,221页

共引文献20

同被引文献20

  • 1韩蓁,张媛丽,苟文丽,李芬,金辉,王凤琴.羊水偏少与不良围产结局的病例对照研究[J].国外医学(妇幼保健分册),2005,16(3):131-132. 被引量:9
  • 2王玉玲,其木格.基质金属蛋白酶及抑制物在妇产科的应用[J].国外医学(妇幼保健分册),2005,16(3):184-186. 被引量:4
  • 3王德智,李辉.胎膜早破的处理[J].中国实用妇科与产科杂志,1996,12(1):11-12. 被引量:30
  • 4高树生.B超监测羊水技术的评价及其在高危妊娠监护中的应用进展[J].实用妇产科杂志,1996,12(3):131-134. 被引量:23
  • 5乐杰.妇产科学[M].第6 版.北京:人民卫生出版社,2003:145-146.
  • 6Fortunato SJ,Menon R.Secreening of novel matrix metalloproteinases (mmps) in human fetal membranes[J]J Assist Reprod Genet,2002,19(10):483-486.
  • 7Brace RA.Physiology of amniotic fluid volume regulation[J].Clin Obstet Gynecol,1997,40(2):280-289.
  • 8Yoon BH,Kim YA,Romero R,et al.Association of oligohydramnios in women with preterm premature rupture of membranes with an inflammatory response in fetal,amniotic,and maternal compartments[J].AmJ Obstet Gynecol,1999,18(4):784-788.
  • 9乐杰.妇产科学(第6版)[M].北京:人民卫生出版社,2003.224-227.
  • 10Everett F, Magann M D, Mary J, et al. Does an amniotic fluid index of≤5cm necessitate delivery in high-risk pregnancies? A case-control study[J]. Am J Obstet Gynecol, 1999,180(6):1354- 1357.

引证文献4

二级引证文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部