期刊文献+

新型羟基磷灰石涂层镁合金生物学毒性及相容性观察 被引量:3

The Observation of Biology Cytotoxicity and Biocompatibility of the New Magnesium Alloy with HA Coated
在线阅读 下载PDF
导出
摘要 目的评价羟基磷灰石(HA)涂层的两种合金Mg-4.0Zn-0.5Sr(Wt.%)和Mg-4.0Zn-1.5Sr(Wt.%)的细胞毒性和生物相容性。方法先制备HA涂层Mg-4.0Zn-0.5Sr和Mg-4.0Zn-1.5Sr两种合金,再进行浸提液的制备、测定其镁离子浓度、培养小鼠成纤维细胞L929、测定MTT细胞活力及溶血率。结果 Mg-4.0Zn-1.5Sr合金浸提液的pH值高于Mg-4.0Zn-0.5Sr合金(P<0.05),但镁离子浓度低于Mg-4.0Zn-0.5Sr合金(P<0.05),相对增殖度无统计学差异(P>0.05),但溶血率低于Mg-4.0Zn-0.5Sr合金(P<0.05)。24、48、72 h培养后,对L929细胞的计数显示,两合金组细胞数量减低,但与对照组比较无统计学差异(P>0.05)。结论 Mg-4.0Zn-0.5Sr和Mg-4.0Zn-1.5Sr两种镁合金无细胞毒性,生物相容性较好,有进一步研究应用的价值。 Objective To appraise cytotoxicity and biocompatibility of Mg-4.0Zn-0.5Sr alloy and Mg-4.0Zn-l.5Sr alloy,respectively. Methods Both of the magnesium alloy with hydroxyapatite (HA) coated were prepared firstly,then the extracts of the alloy samples were picked-up to determine the magnesium ion concentration, and through the cultivated of the fibroblasts L929, the cell vigor of MTF colorimetry assessment and hemolysis ratio were obtained. Results The pH of the extract of Mg-g.0Zn-l.5Sr alloy is higher than that of Mg-4.0Zn- 0.5Sr alloy (P 〈 0.05 ), but the magnesium ion concentration of Mg-4.0Zn-l.5Sr alloy is lower than that of Mg-4.0Zn-0.5Sr alloy, as well as both of the relative growth rate (RGR) are similar and the hemolysis ratio of Mg-4.0Zn-l.5Sr alloy is lower than that of Mg-4.0Zn-0.5Sr al- loy (P 〈 0.05 ). Through 24 h,48 h and 72 h cultivated,the count of L929 cell is shown that both counts of the alloys are decreased slightly and there are not marked difference compared with the comparison group. Conclusion Because the cytotoxicity of both Mg-4.0Zn-0.5Sr al- loy and Mg-4.0Zn-l.5Sr alloy is not shown and there is a better biocompatibility,the further study is needed.
出处 《中国医科大学学报》 CAS CSCD 北大核心 2013年第4期304-306,共3页 Journal of China Medical University
基金 国家自然科学基金资助项目(51074049) 国家自然科学基金研究重点项目(51034002)
关键词 镁合金 生物学 毒性 相容性 羟基磷灰石 magnesium alloy biology cytotoxicity biocompatibility hydroxyapatite
  • 相关文献

参考文献5

  • 1王彩梅,周学玉,孙元,贺靠团.外科植入物-骨关节假体材料的选择[J].生物骨科材料与临床研究,2006,3(1):4-7. 被引量:11
  • 2訾炳涛,王辉.镁合金及其在工业中的应用[J].稀有金属,2004,28(1):229-232. 被引量:93
  • 3Amir YS, Mohammad AS, Seyed SH. Biological evaluation of partially stabilized zirconia added HA/HDPE composites with osteoblast and fibroblast cell lines [ J ]. J Mater Sci, 2008,19( 1 ) : 2359-2365.
  • 4Erdmann N,Angrisani N,Reifenrath J,et al. Biomechanical testing and degradation analysis of MgCaO.8 alloy screws : A comparative in vivo study in rabbits [J]. Acta Biomater,2011,7(3 ) : 1421-1428.
  • 5Zhang EL, Yin DS,Xu LP, et al. Microstructure, mechanical and cor- rosion properties and biocompatibility of Mg-Zn-Mn alloys for biomed- ical application [J]. Mater Sei Eng A,2010,527 (13-14):3195- 3199.

二级参考文献16

  • 1叶久新,陈明安,周健,付杰兴.镁合金及其成型技术在工业中的应用[J].湖南大学学报(自然科学版),2002,29(S1):112-116. 被引量:23
  • 2上海交通大学.镁科技发展战略研究 :内部资料[R].,..
  • 3冶金工业部情报标准研究所.有色金属常识[M].北京: 冶金工业部情报标准研究所,1972..
  • 4[2]B.Brunski,"The Influence of Force,Motion,and Related Quantities on the Response of Bone to Implants,"in Non-Cemented Total Hip Arthroplasty (R.Fitzgerald,Jr.,ed.),Raven Press Ltd.,New York,pp.721 (1988).
  • 5[3]Toksvig LS,Jorn LP,Ryd L,et al.Hydroxyapatite enhanced tibial prosthetic fixation.Clin-Orthop.2000.
  • 6[4]Cowin,S.C.,Bone Poroelasticity,J.Biomechanics,32,218-238,1999.
  • 7[5]《中国航空材料手册》编委会,《中国航空材料手册》.第2卷,高温变形合金、铸造高温合金,第二版.中国标准出版社,2002:510-526.
  • 8[6]《中国航空材料手册》编委会,《中国航空材料手册》.第4卷,钛合金铜合金,第二版.中国标准出版社,2001:104-131.
  • 9[12]Effects of in vitro wear of machined and molded UHMWPE tibial inserton TKR kinematics; Benson,L.C.,DesJardins,J.D.and LaBerge,M.; Journal of Biomedical Materials Research (58) 496-504,2001.
  • 10汪之清.国外镁合金压铸技术的发展[J].铸造,1997,46(8):48-51. 被引量:71

共引文献98

同被引文献30

引证文献3

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部