期刊文献+

室间质量评价与临床检验结果互认的可行性研究 被引量:19

Study on external quality assessment and the feasibility of result inter-accreditation for clinical laboratory
在线阅读 下载PDF
导出
摘要 目的分析江西省二级医院以上实验室的2004年至2011年连续8年的5个检验专业科目的室间质评数据,为检验结果在实验室间的互认提供可行性依据。方法采用统一订购的无生物危害的质控品(包括临床化学17项、血液6项、出凝血4项、乙肝、丙肝标志物和尿液干化学8项)进行实验室能力比对检验(proficiency testing,PT),要求在规定时间内进行测定并回报有效数据。结果三级医院在临床化学17项和临床血液6项检验的8年合并PT合格率强于二级医院,分别为94%对79%和87%对66%(P<0.05),差异有统计学意义;而在临床出凝血4项、HBV/HCV标志物和尿液干化学8项检验方面,二、三级医院的8年合并PT合格率分别为70%对83%、87%对94%、和86%对94%,差异无统计学意义(P>0.05)。结论实验室室间质评可以作为检验结果互认的认定依据。 Objective To analyze the data of external quality assessment (EQA) items for clinical laboratory from 2004 to 2011 in all level two and level three hospitals in Jiangxi province, and to provide the evidence for result inter-accreditation of clinical laboratory tests. Methods All level two and level three hospitals were required to participate the EQA program organized by Jiangxi Provincial Center for Clinical Laboratory and to detect 5 items including clinical chemistry, clinical hematology, blood co- agulation, immune markers of hepatitis and urine dry chemistry.All results of EQA from 2004 to 2011 were collected and analyzed statistically by proficiency testing panel (PT) according to state criteria GB/20032301-T-361. The passing rates were calculated with PT scoring, and the coefficients of variation of every test items were compared in all participating laboratories. PT scoring was calculated according to allowable error: PT scored 100 when the test result was in the range of allowable error, while PT scored 0 when test resuh was out of the range of allowable error. The single item was considered passing when the mean PT score of ten samples was more than 80%. Results The passing rates of level three hospitals were higher than those of level two hospitals in tests of clinical chemistry (94% vs 79%, P〈0.05) and clinical hematology (87% vs 66%, P〈0.05).But there were no statistical sig- nificances in tests of blood coagulation (83% vs 70%, P〉0.05), immune markers of hepatitis (94% vs 87%, P〉0.05) and urine dry chemistry(94% vs 86%, P〉0.05) between level three hospitals and level two hospitals. Conclusion The scores of EQA items would provide the evidences of result inter-accreditation among different clinical laboratories.
出处 《实验与检验医学》 CAS 2013年第2期121-124,194,共5页 Experimental and Laboratory Medicine
基金 江西省卫生厅科技项目(编号:20061022)
关键词 质量控制 能力比对检验 结果互认 临床检验 External quality assessment Proficiency testing Inter-accreditation Clinical laboratory
  • 相关文献

参考文献8

  • 1中华人民共和国卫生部.卫办医发[2006]32号卫生部办公厅关于医疗机构间医学检验、医学影像检查互认有关问题的通知[S].北京:卫生部.2006.
  • 2中华人民共和国卫生部.卫办医发[2010]108号卫生部办公厅关于加强医疗质量控制中心建设推进同级医疗机构检查结果互认工作的通知[S].北京:卫生部,2010.
  • 3叶应妩,王毓三,申子瑜.全国临床检验操作规程[M].第3版,南京东南大学出版社,2006:62.
  • 4Shahangian S.Proficiency testing in laboratory medicine:uses and limitations[J].Arch Pathol Lab Med,1998,122(1): 15-30.
  • 5Johnson PR.The contribution of proficiency testing to improving laboratory performance and ensuring quality patient care [J].Cliu Leadersh Manag Rev, 2004,18(6) : 335-341.
  • 6吴时耕,张鹰,万本愿,王文丁,姜青龙.县级以上医院实验室质量控制与检验结果相互认可的研究[J].实验与检验医学,2011,29(5):519-522. 被引量:27
  • 7万本愿,王文丁,钟晓婷,姜青龙,李胜远,吴茂红,熊玉根,吴时根,陈明生.2003年江西省县级以上医院检验科综合质量管理现场考核情况分析[J].中国医院管理,2004,24(7):49-50. 被引量:3
  • 8Bais R. EQA from an Australian Perspective[J]. Clin Biochem Rev, 2007,28 (4): 175 - 178.