摘要 In this study, the polyacrylate intraocularr lens is irradiated by argon ion which can produce free radicals. In order to obtain better hydrophilic and lower platelets adhesion, monomer vinyl pyrrolidone (NVP) is grafted onto the hydrophobic polyacrylate intraocular lens surface in a certain reaction conditions. Specific changes in intraocular lens are detected by static contact angle (CA), scanning electron microscope (SEM) and light transmittance. The results show that this surface modification can greatly improve its hydrophilic character and surface formation. In this study, the polyacrylate intraocularr lens is irradiated by argon ion which can produce free radicals. In order to obtain better hydrophilic and lower platelets adhesion, monomer vinyl pyrrolidone (NVP) is grafted onto the hydrophobic polyacrylate intraocular lens surface in a certain reaction conditions. Specific changes in intraocular lens are detected by static contact angle (CA), scanning electron microscope (SEM) and light transmittance. The results show that this surface modification can greatly improve its hydrophilic character and surface formation.
出处 《Chinese Journal of Biomedical Engineering(English Edition)》 2013年第1期29-36,共8页 中国生物医学工程学报(英文版)
基金 National Natural Science of Foundation of China grant number:81070716
关键词 hydrophobic polyacrylate intraocular lens vinyl pyrrolidone argon ion irradiation graft surface modification 聚丙烯酸酯 表面改性 晶状体 疏水性 人工 乙烯基吡咯烷酮 扫描电子显微镜 血小板粘附
  • 相关文献

参考文献16

  • 1Learning DV. Practice styles and preferences of ASCRS members--2003 survey[J]. Cataract Refractive Surgen, 2004,30(4) : 892-900.
  • 2Kaufman HE, Katz J, Valenti J, ct al. Corneal endothelium damage with intraocular lenses: contact adhesion between surgical materials and tissue[J]. Science, 1977,198(4316):525-527.
  • 3Lin Lin, Wang Yao, Huang Xiaodan, et al. Modification of hydrophobic acrylic intraocular lens with poly(ethylene glycol) by atmospheric pressure glow discharge: A facile approach[J]. Applied Surface Science,2010,256 (24): 7354-7364.
  • 4Xu Zhikang, Nie Fuqiang, Qu Chao, et al. Tethering poly (ethylene glycol)s to improve the surface biocompatibility of poly(acrylonitrile-co-maleic acid) asymmetric membranes[J]. Biomaterials, 2005, 26(6): 589-598.
  • 5Dorey MW,Brownstein S,Hill VE,et al. Proposed pathogenesis for the delayed postoperative opacification of the hy- droview hydrogel intraocular lens[J]. Ameriean Journal of Ophthalmology, 2003,135(5):591-598.
  • 6Taboada-Esteve JF, Hurtado-Sarri 6 M, Duch-Samper AM, et al. Hydrophilic acrylic intraocular lens clouding: A clinicopathological review[J]. European Journal of Ophthalmology 2007,17(4):588-594.
  • 7Wei Yanlin, Ya Yashao, Liu Peng, et al. Surface modification of hydrophobic PMMA intraocular lens by the immobi- lization of hydroxycthyl methacrylate for improving application in ophthalmology[J]. Plasma Chemistry and Plasma Processing,2011,31:811-825.
  • 8Yao Ke, Huang Xiaodan, Huang Xiaojun, et al. Improvement of the sui"face biocompatibility of silicone intraocular lens by the plasma-induced tethering of phospholipid moieties[J]. Journal of Biomedical Materials Research Part A, 2006, 78A(4): 684-692.
  • 9Wan Yuqing, Qu Xue, Lu Jun, et al. Characterization of surface property of poly (lactide-co-glycolide) after oxygen plasma treatment[J]. Biomaterials, 2004, 25(19):4777-4783.
  • 10Shen Hong, Hu Xixue, Yang Fei, et al. Combining oxygen plasma treatment with anchorage of cationized gelatin for enhancing cell affinity of poly(lactide-co-glycolide)[J]. Biomaterials,2007, 28(29):4219-4230.

同被引文献5

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部