摘要 目的 探讨双极射频切除止血设备Habib 4X在肝脏切除手术中的应用效果.方法 使用Habib 4X肝脏切除手术18例(腹腔镜肝切除1例次).原发性肝癌患者9例(其中合并肝硬化3例),胆囊癌3例,左肝内胆管结石,肝内胆管炎,左肝萎缩3例,巨大肝血管瘤3例.在开腹和腹腔镜肝切除手术中,使用手执式一次性射频消融设备Habib 4X,垂直插入肝脏,沿所需路线进行切割.在电极之间所产生可控的射频能量,对肝脏组织包括胆管和血管进行封闭,然后使用手术刀进行肝切除.结果 肝切除过程中均未行肝门血管阻断.术中平均出血量180ml(50~350ml),无输血病例,无胆漏发生,平均手术时间225min,无围手术期死亡病例.结论 严格选择手术适应证的前提下,Habib 4X切除肝脏是安全的,可以作为肝脏切除技术选择. Objective To investigate the application effect of Habib 4X radiofrequency-assisted bipolar hemostatic device in liver resection surgery. Methods From February 2010 to August 2011,18 patients accepted liver resection with the device( laparoscopic liver resection in 1 case) ,including 9 cases of primary, liver cancer( combined liver cirrhosis in 3 cases) ,3 cases of gallbladder cancer,3 cases of the left intrahepatic bile duct stones, intrahepatic cholangitis and left liver atrophy and 3 cases of giant hepatic hemangioma. In the open and laparoscopic liver resection, a handheld disposable radiofrequency ablation device Habib 4X was inserted into the liver vertically and cut along the desired route. A controllable radio frequency energy generated by electrodes was used to seal the liver tissue, including the bile duct and blood vessels, and then the scalpel was used for liver resection. Results During the liver resection process,no hepatic portal occlusion was performed. The intraoperative mean blood loss was 180 m1(50 - 350 ml). No blood transfusion or bile leakage occurred. The mean operative time was 225 minutes. There were no perioperative deaths. Conclusion Based on the premise of strict selection of surgical indication, liver resection by Habib 4X is safe,which could be a choice as liver resection technique.
出处 《临床外科杂志》 2013年第5期343-345,共3页 Journal of Clinical Surgery
基金 首都医科大学基础临床科研合作课题资助项目(课题编号:10JL25)
关键词 肝切除 双极射频切除止血 Habib 4X liver resection bipolar radiofrequency resection for hemostasis Habib 4X
  • 相关文献

参考文献6

  • 1Pai M, Jiao LR, Khorsandi S, et al. Liver resection with bipolar radiofre- quency device : Habib 4X [ J ]. HPB (Oxford) ,2008,10 (4) :256-260.
  • 2Pai M, Frampton AE, Mikhail S, et al. Radiofrequency assisted liver re- section : analysis of 604 consecutive cases [ J ]. Eur J Surg Oncol, 2012, 38(3) :274-280.
  • 3Pai M, Spalding D, Jiao L, et al. Use of bipolar radiofrequency in paren- chymal transection of the liver, pancreas and kidney [ J ]. Dig Surg, 2012,29( 1 ) :43-47.
  • 4Poosa HPAM, Daryanania D, Klaasea JM. Partial splenectomy for splenic cyst using a bipolar radiofrequency device [ J ]. Gastroenterology Re- search,2009,2(4) :242-244.
  • 5Zacharoulis D, Lazoura O, Sioka E, et al. Radiofrequency-assisted hemo- stasis in a trauma model : a new indication for a bipolar device [ J ]. J Laparoendosc Adv Surg Tech A, 2010,20 ( 5 ) :421-426.
  • 6Gadiyaram S, Shetty N. Laparoscopic resection of giant liver hemangioma using laparoscopic Habib probe for parenchymal transection [ J 1. J Min- im Access Surg,2012,8(2) :59-61.

同被引文献33

  • 1黎介寿.对Fast-track Surgery(快通道外科)内涵的认识[J].中华医学杂志,2007,87(8):515-517. 被引量:369
  • 2江志伟,黎介寿,汪志明,李宁,柳欣欣,李伟彦,朱四海,刁艳青,佴永军,黄小静.胃癌患者应用加速康复外科治疗的安全性及有效性研究[J].中华外科杂志,2007,45(19):1314-1317. 被引量:242
  • 3鲍世韵,余小舫,马扬,贾随旺,郑锦锋,张卓,刘嘉林,方锡明,周汉新.Ligasure血管闭合系统在腹腔镜肝切除手术中的初步应用[J].中华肝胆外科杂志,2007,13(9):635-636. 被引量:2
  • 4Weber JC, Navarra G, Jiao LR, et al. New technique for liver resection using heat coagulative necrosis [ J ]. Ann Surg, 2002, 236(5 ) :560-563.
  • 5Stavrou GA,Tzias Z, von Falck C, et al. Hepatic reseetion using heat eoagulative necrosis. First report of successful triseg- menteetomy after hypertrophy induction [ J]. Langenbecks Areh Surg,2007,392( 1 ) :95-97.
  • 6Wagman LD, Lee B, Castillo E,et al. Liver resection using a four prong radiofrequency transection device [ J ]. Am Surg, 2009,75 (10) :991-994.
  • 7王迪.Hahib4X手术刀,“兵不血刃”除肿瘤[N].医药经济报,2005-9-23(8).
  • 8Ayav A, Jiao L, Dickinson R, et al. Liver resection with a New muhiprobe bipolar radiofrcquency device [ J ]. Arch Surg, 2008, 143(4) :396-401 ;discussion 401.
  • 9Pai M, Jiao LR, Khorsandi S, et al. Liver resection with bipolar radio fi'equency device : Habib 4X [ J ]. HPB ( Oxford ) ,2008,10 (4) : 256-260.
  • 10潘光栋,杨建青,褚光平,毛盛名,刘振,袁林,肖亿,谭盛强.Ligasure联合超声刀在肝胆外科开腹手术中的应用[J].微创医学,2009,4(4):340-342. 被引量:10