本文通过分析供电可靠性的影响因素,采用故障后果分析法,对简单辐射式配电网评估可靠性指标,并在不同情况下进行对比研究。研究表明,有备用电源和自动分段开关情况下平均可用度最高,停电次数最少,很大程度上提高了系统的可靠性。
By analyzing the influence factors of the power supply reliability, the fault consequence analysis method to evaluate simple radial distribution network reliability index and comparative study in different situations. Research shows that the highest average availability in the have a spare power supply and automatic section switch, the least number of blackout, to a great extent improve the reliability of the system.