期刊文献+

DVR解剖型桡骨掌侧锁定接骨板治疗桡骨远端骨折 被引量:7

Treatment of distal radius fracture with DVR plate
原文传递
导出
摘要 目的探讨开放复位DVR解剖型桡骨掌侧锁定接骨板治疗桡骨远端骨折的疗效。方法回顾性分析自2010年12月。2012年4月用DVR解剖型桡骨掌侧锁定接骨板治疗的不稳定桡骨远端骨折15例。结果15例获随访8~24个月,平均14个月,所有骨折均于术后3个月内愈合。术后平均掌倾角、尺偏角、尺骨变异分别为(7.9±2.3)°、(21.5±3.4)。、(-0.20±1.21)mm,末次随访时平均掌倾角、尺偏角、尺骨变异分别为(7.80±2.24)°、(21.3±3。4)°、(-0.07±1.22)mm,二者差异无统计学意义。按照改良的Green—O'Bfien功能评分,腕关节功能:优11例,良2例,可1例,差1例。结论开放复位DVR解剖型桡骨掌侧锁定接骨板治疗桡骨远端骨折具有操作简单、骨折复位好、固定牢固、可早期功能锻炼、腕关节功能恢复满意的优点。是治疗桡骨远端比较理想的方法。 Objective To investigate the efficacy of open reduction and internal fixation with DVR plate in the treatment of distal radius fracture. Methods From December 2010 to April 2012, 15 patients with unstable distal radius fractures were treated with open reduction and internal fixation with DVR plate. Results All the patients were followed up for 8-24 months (average, 14 months). All fractures healed within 3 months. The postoperative mean volar tilt, radial inclination and ulnar variance were (7.9±2.3)°, (21.5±3.4)°, (-0.20±l.21)mm, respectively; and the final mean volar tilt, radial inclination and ulnar variance were (7.80±2.24)°, (21.3±3.4)°, (-0.07±1.22)mm, respectively, between which there was no statistical significance. According to the Modified Green-O'Brien Scale, the functional results were excellent in 11 patients, good in 2, fair in 1, and bad in 1. Conclusion It is an ideal way to treat the distal radius fracture with open reduction and internal fixation with DVR plate, which has the advantages of simple manipulation, good reduction, rigid fLxation, early return to functional exercises and good recovery of wrist function.
出处 《中国骨与关节损伤杂志》 2013年第9期837-839,共3页 Chinese Journal of Bone and Joint Injury
关键词 桡骨远端骨折 内固定 DVR钢板 切开复位术 Distal radius fracture Internal fLxation DVR plate Open reduction
  • 相关文献

参考文献13

  • 1Hove LM,Nilsen PT,Fumes O,et al. Open reduction and internal fixation of displaced intraarticular fractures of the distal redius:31 patients followed for 3 to 7 years [J]. Acta Orthop Scand,1997,68: 59-63.
  • 2Arora R,Lutz M, Hennerbichler A, etal. Complications following in- ternal fixation of unstable distal radius fracture with a palmar lock- ing-plate[J]. J Orthop Trauma,2007,21(5):316--322.
  • 3Ilyas AM. Surgical approaches to the distal radius [J]. Hand (N Y), 2011,6(1):8-17.
  • 4M, Pervaiz Anjum,Faisal Nazeer Hussain,Ahmad Ali. Postoperative wrist movements in percutaneous fLxation by K-wire of Colles' fracture[J]. J Medical Channel,2010,16(2):331-333.
  • 5张成亮,陈德权,陶铁成,郑波.桡骨远端不稳定骨折的手术治疗[J].中国骨与关节损伤杂志,2010,25(3):272-273. 被引量:16
  • 6Orbay JL. The treatment of unstable distal radius fractures with volar fixation[J]. Hand Surg,2000,5(2) : 103-112.
  • 7Orbay JL,Fernandez DL. Volar fixed-angle plate fixation for unsta- ble distal radius fractures in the elderly patient [J]. J Hand Surg (Am) ,2004,29:96-102.
  • 8吴学元,马巍,任国文,王振汉.锁定加压钢板治疗四肢骨折的临床应用[J].中国骨与关节损伤杂志,2009,24(2):169-170. 被引量:49
  • 9Drobetz H,Bryant AL,Pokorny T,et al. Velar fixed-angle plating of distal radius extension fractures:influence of plate position on sec- ondary loss of roduction-a biomechanic study in a cadaveric model [J]. J Hand Surg Am,2006,31(4):615-622.
  • 10黄伟松,冯小兵,杨立国,李程伟.掌侧斜T形锁定加压钢板治疗桡骨远端不稳定骨折[J].中国骨与关节损伤杂志,2011,26(3):261-262. 被引量:10

二级参考文献15

共引文献76

同被引文献53

  • 1陈凯,樊健,袁锋,闵晓辉,朱辉,俞光荣.锁定钢板在老年桡骨远端C2、C3型骨折中的应用[J].中国骨与关节损伤杂志,2013,28(S1):53-54. 被引量:4
  • 2葛顺杰,陆茂德,仇继任,章泰丰,罗坤烈,葛艺.掌侧入路锁定钢板内固定治疗不稳定桡骨远端骨折疗效分析[J].中国骨与关节损伤杂志,2013,28(S1):54-55. 被引量:15
  • 3Fernandez DL,Jupiter JB. Fractures of the distal radius:a practicalapproach to management [M]. New York : Springer -Verlag, 1996 :145-151.
  • 4Dienst M, Wozasek GE, Seligson D. Dynamic external fixation fordistal radius fractures [J]. Clin Orthop Relat Res, 1997,338 : 160 -171.
  • 5Westphai T’Piatek S,Schubert S,et al. Outcome after surgery ofdistal radius fractures:no differences between external fixation andORIF [J], Arch Orthop Trauma Surg,2005,125(8):507-514.
  • 6Herron M,Faraj A,Craigen MA. Dorsal plating for displaced intra-articular fractures of the distal radius[J]- Injury,2003,34(7) :497-502.
  • 7Hershman SH, Immerman I,Bechtel C, et al. Hie effects of pronatorquadratus repair on outcomes after volar plating of distal radiusfractures[J]. J Orthop Trauma,2013,27(3): 130-133.
  • 8Lattmann T,Dietrich M,Meier Ctet al. Comparison of 2 surgicalapproaches for volar locking plate osteosynthesis of the distal ra-dius[J]. J Hand Sui^ Am,2008,33(7):1135-1143.
  • 9Kamano Honda Y,Kazuki Ktet al. Palmar plating for dorsallydisplaced fractures of the distal radius [J]. Clin Orthop Relat Res,2002,397:403^08.
  • 10Gereli A.Nalbantoglu U.KocaogIu B,et al. Comparison of palmarlocking plate and K—wire augmented external fixation for intra-ar-ticular and comminuted distal radius fractures [J]. Acta OrthopTraumatol Ture,2010,44(3):212-219.

引证文献7

二级引证文献53

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部